Bridge-plating osteosynthesis of 20 comminuted subtrochanteric fractures with dynamic hip screw.

Chang Gung Med J

Division of Trauma & Emergency, Department of Orthopedic Surgery, Chung Gung Memorial Hospital, Taipei, Taiwan, ROC.

Published: December 2002

Background: A prospective clinical trial was conducted to evaluate the conjunctive use of an extramedullary device and the bridge-plating technique in the treatment of comminuted subtrochanteric fractures with major extension into the femoral shaft.

Methods: A Winquist criteria was used to classify 3 fracture patterns. The type 3 fractures were excluded from this study because of great extent of the fracture zone for which the bridge-plating technique is not indicated. There were 14 men and 6 women, with a mean age of 49 (range, 17-76) years. A dynamic hip screw (DHS) with a long side plate was chosen as the fixation device because of the small learning curve.

Results: The fractures united at a mean of 7.6 (range, 3-15) months postoperatively. Mobility was scored at 9 points in 18 patients and 6 points in 2 patients (Mobility score of Parker & Palmer). Pain was absent in 14, mild in 3, and moderate in 3 patients. Two limbs were shortened by 1 and 1.5 cm, respectively.

Conclusion: Our results indicate that DHS fixation using the bridge-plating technique leads to union of all comminuted Winquist types 1 and 2 fractures without major complications, and it is a valuable alternative to new intramedullary devices. This procedure offers the significant advantage of being less technically demanding.

Download full-text PDF

Source

Publication Analysis

Top Keywords

bridge-plating technique
12
comminuted subtrochanteric
8
subtrochanteric fractures
8
dynamic hip
8
hip screw
8
fractures major
8
points patients
8
fractures
5
bridge-plating
4
bridge-plating osteosynthesis
4

Similar Publications

Background: This study compares the difference in the clinical and radiologic outcomes when minimally invasive plate osteosynthesis (MIPO) technique is performed with or without using a positional screw in the treatment of humeral shaft fractures.

Methods: From January 2010 to January 2021, a retrospective study was conducted on a total of 63 patients who underwent the MIPO technique for the treatment of humeral shaft fractures. We divided these patients into 2 groups: in group I, patients underwent MIPO without a positional screw; in group II, patients underwent MIPO with a positional screw.

View Article and Find Full Text PDF

Lisfranc injuries were previously described as fracture-dislocations of the tarsometatarsal joints. With advancements in modern imaging, subtle Lisfranc injuries are now more frequently recognized, revealing that their true incidence is much higher than previously thought. Injury patterns can vary widely in severity and anatomy.

View Article and Find Full Text PDF

Background: Adult humeral shaft fractures have traditionally been managed conservatively, but surgical intervention is considered for displaced fractures or when conservative treatment is unlikely to be successful. The optimal surgical approach remains controversial, with open reduction and internal fixation (ORIF) using plates and screws considered the gold standard. However, concerns about soft tissue damage have led to the development of less invasive techniques, such as anterior bridge plating using minimally invasive plate osteosynthesis (MIPO).

View Article and Find Full Text PDF

Introduction: Surgical treatment of distal femoral fractures (DFFs) in osteoporotic bone is challenging despite improvements in hardware and surgical techniques. The occurrence and degree of secondary displacement during healing after bridging plate fixation are still unknown. This study aimed to assess the occurrence and degree of secondary displacement in healing DFFs in elderly patients and correlate the secondary displacement to body mass index, bone density, and weight-bearing regimen.

View Article and Find Full Text PDF

Purpose: Our objective was to determine if patients with a distal radius fracture and concomitant lower-extremity fracture benefit from bridge plating when compared with volar plating.

Methods: We conducted a retrospective cohort study evaluating distal radius fractures fixated by bridge or volar plating in orthopedic trauma patients with a concomitant lower-extremity fracture. Patients were prescribed a platform walker and followed for gait aid use and both upper and lower-extremity fracture-related outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!