Study Design: Forty-four consecutive thoracic idiopathic adolescent curves surgically treated between 1995 and 1999 at one institution were analyzed. All were thoracic curves; there were no lumbar curves, double major curves, or triple major curves.

Objectives: To study the clinical and radiographic results for these 44 patients.

Summary Of Background Data: There is currently ongoing discussion regarding the "best treatment" for right thoracic idiopathic scoliosis.

Methods: Patients were administered preoperative and postoperative Scoliosis Research Society questionnaires. Radiographs were studied for coronal correction, sagittal correction, junctional deformities two segments above/two segments below, fusion status, loss of correction status, complications, and imbalance of curves above and below. Radiographic analysis was by two independent observers. All patients were treated with bilateral 5.5-mm CD Horizon (M-10) instrumentation. Corrective forces were translational and in situ contouring. An average of 10 hooks and 4 Wisconsin wires were used for an average of 14 fixation points per 11 segments. Follow-up was minimum 2 years to maximum 5 years, with an average of 3-year, 10-month follow-up.

Results: All were out of bed on postoperative day 1; none was braced after surgery. The average preoperative thoracic curve was 56 degrees; the average ultimate postoperative curve was 31 degrees (P = 0.0001). In the sagittal plane T5-T12 averaged 22 degrees preoperation and 20 degrees postoperation. For the complete study group (n = 44), the Cobb measurement (P = 0.001) and apical vertebral translation of the lumbar curve (P = 0.001) below improved. For the false double major curve (n = 11) patterns, the unfused lumbar curve averaged preoperation 46 degrees and postoperation 27 degrees (P = 0.0001). There were no neurologic deficits, no wound infections, and no respiratory complications. In regards to the Scoliosis Research Society questionnaires, significant (P < 0.05) changes preoperative to ultimate postoperative were found for questions 3, 5, 11, and 14.

Conclusion: "Satisfactory" results were obtained in 44 patients treated with this technique. The complication rate was low and the fusion rate was high. Posterior treatment as described above produces reasonable and dependable results.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00007632-200209150-00018DOI Listing

Publication Analysis

Top Keywords

wisconsin wires
8
thoracic idiopathic
8
double major
8
scoliosis society
8
society questionnaires
8
patients treated
8
curve degrees
8
ultimate postoperative
8
degrees 00001
8
preoperation degrees
8

Similar Publications

Many organisms maintain generalized stress responses activated by adverse conditions. Although details vary, a common theme is the redirection of transcriptional and translational capacity away from growth-promoting genes and toward defense genes. Yet the precise roles of these coupled programs are difficult to dissect.

View Article and Find Full Text PDF

Embryo implantation requires tightly coordinated signaling between the blastocyst and the endometrium, and is crucial for the establishment of a uteroplacental unit that persists until term in eutherian mammals. In contrast, marsupials, with a unique life cycle and short gestation, make only brief fetal-maternal contact and lack implantation. To better understand the evolutionary link between eutherian implantation and its ancestral equivalent in marsupials, we compare single-cell transcriptomes from the receptive and non-receptive endometrium of the mouse and guinea pig with that of the opossum, a marsupial.

View Article and Find Full Text PDF

In congenital stationary night blindness, type 2 (CSNB2)-a disorder involving the Ca1.4 (L-type) Ca channel-visual impairment is mild considering that Ca1.4 mediates synaptic release from rod and cone photoreceptors.

View Article and Find Full Text PDF
Article Synopsis
  • This study analyzed how different constant temperatures (12°C, 37°C, and 50°C) affect the unloading force of three types of nickel-titanium (NiTi) archwires used in orthodontics.
  • Three types of archwires tested included superelastic, heat-activated at 25°C, and thermally activated at 35°C, with results measured through a three-point bending test.
  • Findings revealed that all wire types demonstrated thermal sensitivity, with unloading forces increasing at higher temperatures and varying responses among the types, particularly showing the greatest sensitivity in the thermally activated Ti-Lite® wire.
View Article and Find Full Text PDF

Magnetic Detection of Neural Activity by Nanocoil Transducers.

Nano Lett

October 2024

Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.

Electrophysiological recordings from brain cells are performed routinely using implanted electrodes, but they traditionally require a wired connection to the outside of the brain. A completely passive, wireless device that does not require on-board power for active transmission but that still facilitates remote detection could open the door for mass-scale direct recording of action potentials and transform the way we acquire brain signals. We present a nanofabricated coil that forms a neuroelectromagnetic junction, yielding a highly enhanced magnetic field transduction of electrophysiology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!