Objectives: To look for possible regional differences in the prevalence of rheumatoid factor (RF) in the presence and absence of arthritis.

Methods: The study covered a representative sample of the Finnish population aged 30 years or over, primarily comprising 8000 people, of whom 7217 participated in the field survey carried out in 1978-80. RF from serum samples from 7116 subjects was determined by the Waaler-Rose (sensitised sheep cell agglutination) test. Titres >or=32 were regarded as positive and titres >or=128 as strongly positive. Arthritis was diagnosed by a thorough clinical examination.

Results: In the absence of arthritis the prevalence of positive and strongly positive RF reactions was 2.1% and 1.0%, respectively. The lowest prevalence of strongly "false positive" RF occurred in south western Finland. After adjustment for age, sex, smoking, and coffee consumption the odds ratio of having a strongly "false positive" RF reaction in eastern Finland was 3.16 (95% confidence interval 1.29 to 7.72) and in northern Finland 2.94 (1.13 to 7.64) compared with south western Finland. The corresponding odds ratio of strongly RF positive arthritis in eastern Finland was 5.08 (1.41 to 18.27).

Conclusion: Regional differences are found in the prevalence of a strongly positive RF reaction in the Finnish population. The findings are in accordance with recent results from another study concerning regional differences in the incidence of rheumatoid arthritis in Finland.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1754504PMC
http://dx.doi.org/10.1136/ard.62.4.353DOI Listing

Publication Analysis

Top Keywords

regional differences
16
prevalence rheumatoid
8
rheumatoid factor
8
factor presence
8
presence absence
8
absence arthritis
8
differences prevalence
8
finnish population
8
positive arthritis
8
prevalence positive
8

Similar Publications

This study employed high-time-resolution systems to examine the transient properties of aerosols and gases emitted from electronic cigarette (EC) puffs. Using a fast aerosol sizer, we measured particle size distributions (PSDs) across various EC brands (JUUL, VUSE, VOOPOO), revealing sizes ranging from 5 to 1000 nm at concentrations of 10 to 10 cm. Most aerosols were found to be in the ultrafine range (below 100 nm), with JUUL-, VUSE-, and VOOPOO-producing aerosols with geometric mean sizes of 19.

View Article and Find Full Text PDF

Understanding the Curvature Effect on the Structure and Bonding of MoC Nanoparticles on Carbon Supports.

ACS Appl Mater Interfaces

January 2025

Departament de Ciència de Materials i Química Física & Institut de Química Teòrica i Computacional (IQTCUB), Universitat de Barcelona, c/Martí i Franquès 1-11, Barcelona 08028, Spain.

The interaction between molybdenum carbide (MoC) nanoparticles and both flat and curved graphene surfaces, serving as models for carbon nanotubes, was investigated by means of density functional theory. A variety of MoC nanoparticles with different sizes and stoichiometries have been used to explore different adsorption sites and modes across models with different curvature degrees. On flat graphene, off-stoichiometric MoC featuring more low-coordinated Mo atoms exhibits stronger interaction and increased electron transfers from the carbide to the carbon substrate.

View Article and Find Full Text PDF

Purpose: Local recurrence of prostate cancer (PCa) after radiation therapy (RT) typically occurs at the site of dominant tumor burden, and recent evidence confirms that magnetic resonance imaging (MRI) guided tumor dose escalation improves outcomes. With the emergence of prostate-specific membrane antigen (PSMA) positron emission tomography (PET), we hypothesize that PSMA-PET and MRI may not equally depict the region most at risk of recurrence after RT.

Methods And Materials: Patients with intermediate- to high-risk PCa and MRI plus PSMA-PET performed before RT were identified.

View Article and Find Full Text PDF

The Accuracy of Cardiac Surface Conduction Velocity Measurements.

JACC Clin Electrophysiol

December 2024

The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.

Background: Conduction velocity (CV) is a measure of the health of myocardial tissue. It can be measured by taking differences in local activation times from intracardiac electrodes. Several factors introduce error into the measurement, among which ignoring the 3-dimensional aspect is a major detriment.

View Article and Find Full Text PDF

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!