The tensor analyzing power components T20 and T21 have been measured in elastic electron-deuteron scattering at the 2 GeV electron storage ring VEPP-3, Novosibirsk, in a four-momentum transfer range from 8.4 to 21.6 fm(-2). A new polarized internal gas target with an intense cryogenic atomic beam source was used. The new data determine the deuteron form factors G(C) and G(Q) in an important range of momentum transfer where the first node of the deuteron monopole charge form factor is located. The new results are compared with previous data and with some theoretical predictions.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.90.072501DOI Listing

Publication Analysis

Top Keywords

tensor analyzing
8
t20 t21
8
elastic electron-deuteron
8
electron-deuteron scattering
8
measurement tensor
4
analyzing powers
4
powers t20
4
t21 elastic
4
scattering tensor
4
analyzing power
4

Similar Publications

Unlabelled: Accurate localization of white matter pathways using diffusion MRI is critical to investigating brain connectivity, but the accuracy of current methods is not thoroughly understood. A fruitful approach to validating accuracy is to consider microscopy data that have been co-registered with MRI of post mortem samples. In this setting, structure tensor analysis is a standard approach to computing local orientations for validation.

View Article and Find Full Text PDF

Background And Purpose: Diffusion tensor imaging (DTI) has been proposed to guide the anisotropic expansion from gross tumor volume to clinical target volume (CTV), aiming to integrate known tumor spread patterns into the CTV. This study investigate the potential of using a DTI atlas as an alternative to patient-specific DTI for generating anisotropic CTVs.

Materials And Methods: The dataset consisted of twenty-eight newly diagnosed glioblastoma patients from a Danish national DTI protocol with post-operative T1-contrast and DTI imaging.

View Article and Find Full Text PDF

Materials with Negative Permittivity or Negative Permeability-Review, Electrodynamic Modelling, and Applications.

Materials (Basel)

January 2025

Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland.

A review of natural materials that exhibit negative permittivity or permeability, including gaseous plasma, metals, superconductors, and ferromagnetic materials, is presented. It is shown that samples made of such materials can store large amount of the electric (magnetic) energy and create plasmonic resonators for certain values of permittivity, permeability, and dimensions. The electric and the magnetic plasmon resonances in spherical samples made of such materials are analyzed using rigorous electrodynamic methods, and the results of the analysis are compared to experimental data and to results obtained with other methods.

View Article and Find Full Text PDF

Background/objectives: Intraneural tumors (INTs) pose a diagnostic challenge, owing to their varied origins within nerve fascicles and their wide spectrum, which includes both benign and malignant forms. Accurate diagnosis and management of these tumors depends upon the skills of the radiologist in identifying key imaging features and correlating them with the patient's clinical symptoms and examination findings.

Methods: This comprehensive review systematically analyzes the various imaging features in the diagnosis of intraneural tumors, ranging from basic MR to advanced MR imaging techniques such as MR neurography (MRN), diffusion tensor imaging (DTI), and dynamic contrast-enhanced (DCE) MRI.

View Article and Find Full Text PDF

Objective: Awake craniotomy is commonly used to resect lesions located near the language area during brain surgery. However, it is often difficult to perform language tasks due to several limitations such as difficulty in awakening during surgery and intraoperative seizures. This study investigated the clinical significance of bidirectional corticocortical evoked potential (CCEP) monitoring as a new approach to evaluate intraoperative language function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!