Objective: This study was performed in order to evaluate patient satisfaction with epilation using an intense pulsed light source.

Methods: Between 1995 and 2000, 416 patients consulted the authors' practice because of unwanted facial and body hair. A total of 309 patients received treatment with a non-coherent, filtered flashlamp intense pulsed light source. In February 2000, a questionnaire was mailed to each patient and 207 replies were obtained.

Results: Overall, 45 (22%) of patients were very satisfied, 93 (45%) were satisfied and 69 (33%) remained unsatisfied with the outcome of light-assisted hair removal. The non-coherent, filtered flashlamp intense pulsed light source satisfactorily removed unwanted dark hair. Hair-free periods from weeks to years could be observed.

Conclusion: Hair removal by a non-coherent, filtered flashlamp intense pulsed light source is an effective and safe method for long-term epilation of unwanted hair. This technique offers a more reliable and practical solution than any other hair removal method, especially for patients with skin irritation and ingrown hair.

Download full-text PDF

Source
http://dx.doi.org/10.1080/147641702321136237DOI Listing

Publication Analysis

Top Keywords

intense pulsed
20
pulsed light
20
non-coherent filtered
12
filtered flashlamp
12
flashlamp intense
12
light source
12
hair removal
12
patient satisfaction
8
unwanted facial
8
facial body
8

Similar Publications

Background: While the effects of sleep deprivation on cognitive function are well-documented, its impact on high-intensity endurance performance and underlying neural mechanisms remains underexplored, especially in the context of search and rescue operations where both physical and mental performance are essential. This study examines the neurophysiological basis of sleep deprivation on high-intensity endurance using electroencephalography (EEG). In this crossover study, twenty firefighters were subjected to both sleep deprivation (SD) and normal sleep conditions, with each participant performing endurance treadmill exercise the following morning after each condition.

View Article and Find Full Text PDF

Transcranial magnetic stimulation (TMS) has been used for many years to study the pathophysiology of amyotrophic lateral sclerosis (ALS). Based on single- or dual-pulse TMS and EMG and/or single motor unit (MU) recordings, many groups have described a loss of central inhibition as an early marker of ALS dysfunction, reflecting a state of cortical 'hyperexcitability'. This conclusion is not without its detractors, however, leading us to reexamine this issue using 4-pulse TMS, shown previously to be more effective for testing central motor pathway functional integrity.

View Article and Find Full Text PDF

Excited-State Proton Transfer Dynamics of Cyanonaphthol in Protic Ionic Liquids: Concerted Effects of Basicity of Anions and Alkyl Carbons in Cations.

J Phys Chem B

January 2025

Department of Applied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoyo 610-0321, Japan.

Excited-state proton transfer (ESPT) reactions of 5-cyano-2-naphthol (5CN2) and 5,8-dicyano-2-naphthol (DCN2) were investigated in protic ionic liquids (PILs) composed of quaternary ammonium (NH) ( = 2, 4, or 8) and hexanoate (CHCOO) using time-resolved fluorescence spectroscopy. The effects of the number of alkyl carbons in the cation and the basicity of the anion on the reaction yield and dynamics were examined. In a series of [NH][CHCOO], fluorescence from the hydrogen-bonding complex (AHBX) of a proton-dissociated form (RO) with a solvent acid in the electronic excited state was observed between the fluorescence bands of an acidic form (ROH) and an anionic form (RO) as in the case of [NH][CFCOO] (Fujii et al.

View Article and Find Full Text PDF

Magnetic Resonance Acoustic Radiation Force Imaging (MR-ARFI).

J Magn Reson Imaging

January 2025

Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.

This review covers the theoretical background, pulse sequence considerations, practical implementations, and multitudes of applications of magnetic resonance acoustic radiation force imaging (MR-ARFI) described to date. MR-ARFI is an approach to encode tissue displacement caused by the acoustic radiation force of a focused ultrasound field into the phase of a MR image. The displacement encoding is done with motion encoding gradients (MEG) which have traditionally been added to spin echo-type and gradient recalled echo-type pulse sequences.

View Article and Find Full Text PDF

Objective: We aim to determine the maximum safe spatial-peak pulse-average intensity (I) of low-intensity focused ultrasound stimulation (LIFUS) in stroke patients and explore its effect on motor learning and corticospinal excitability.

Methods: We adopted the classic 3+3 design to escalate I (estimated in-vivo transcranial value) from 0, 1, 2, 4, 6, to 8 W/cm. Stopping rules were pre-defined: 2-degree scalp burn, clinical seizure, new lesion on diffusion-weighted imaging or major reduction in apparent diffusion coefficient, and participant discontinuation due to any reason.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!