AI Article Synopsis

Article Abstract

Objective: To identify accurately thick melanomas preoperatively by means of a combined approach based on sonography and clinical-videomicroscopic evaluation.

Design: Ultrasonographic thickness measurement, obtained by means of a 20-MHz B-scanner, and identification of clinical and videomicroscopic variables useful in distinguishing between thick and thin melanomas were performed on a training set of 40 melanomas. An algorithm based on echographic, clinical, and videomicroscopic criteria was constructed to develop a method for preoperative evaluation of melanoma thickness and was validated on a test set of 48 melanomas.

Setting: University medical department.

Patients: Eighty-eight patients affected by primary cutaneous melanoma.

Main Outcome Measures: Sensitivity and specificity of the algorithm, with the use of sonographic, clinical, and videomicroscopic data, in thick melanoma identification.

Results: Echographic thickness was calculated for each lesion. On the training set, 2 clinical and 7 videomicroscopic features were identified for distinction between thick and thin melanomas: nonpalpability, central pigment network, central brown globules, and blotches were characteristic of thin melanomas; clinical regression, localized peripheral pigment network, veil, grayish polygonal areas, and blood vessels were characteristic of thick ones. A coefficient was attributed to each variable and a score was obtained for each lesion. The algorithm, developed for preoperative thickness prediction, was validated on the test set, enabling the distinction of thick melanomas with an 86.7% sensitivity and a 100% specificity.

Conclusion: The correct classification of all thin melanomas as such renders this approach suitable in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archderm.139.3.293DOI Listing

Publication Analysis

Top Keywords

clinical videomicroscopic
16
thin melanomas
16
melanoma thickness
8
thick melanomas
8
thick thin
8
training set
8
validated test
8
test set
8
distinction thick
8
pigment network
8

Similar Publications

Background: Chagas disease is a systemic illness with widespread microvascular involvement. Experimental and clinical studies suggest that functional and structural microcirculatory abnormalities might be relevant to the disease progression.

Objectives: To show the presence of sublingual microcirculatory alterations in patients with chronic Chagas disease.

View Article and Find Full Text PDF

Background: Direct assessment of microcirculatory function remains a critical care research tool but approaches for analysis of microcirculatory videomicroscopy clips are shifting from manual to automated algorithms, with a view to clinical application in the intensive care unit. Automated analysis software associated with current sidestream darkfield videomicroscopy systems is demonstrably unreliable; therefore, semi-automated analysis of captured clips should be undertaken in older generations of software. We present a method for capture of microcirculatory clips using current version videomicroscope hardware and resizing of clips to allow compatibility with legacy analysis software.

View Article and Find Full Text PDF

Objective: To investigate sidestream dark field (SDF) videomicroscopy as an objective measure of intestinal viability and determine the effects of enterectomy techniques on intestinal microvasculature in dogs with foreign body obstructions.

Study Design: Prospective, randomized, clinical trial.

Animals: A total of 24 dogs with an intestinal foreign body obstruction and 30 systemically healthy dogs.

View Article and Find Full Text PDF

Green light with a wavelength of 520 nm is commonly used in sidestream dark field (SDF) video microscopes for sublingual microcirculation assessment in clinical practice. However, blue light could obtain a clearer microcirculatory image due to a higher light absorption coefficient of hemoglobin. The aim of this study was to compare the sublingual microcirculatory image quality acquisition and related microcirculatory parameters between 520 nm green light and 415 nm blue light probes in the SDF device named MicroSee V100.

View Article and Find Full Text PDF

The endothelial glycocalyx (EG) determines transvascular fluid fluxes, and influences inflammation, coagulation, and capillary blood flow. The GlycoCheck® software calculates EG thickness using sidestream dark field videomicroscopy recordings. This method has not been evaluated for use in cats.