A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adsorption of sufentanil to epidural filters and catheters. | LitMetric

Adsorption of sufentanil to epidural filters and catheters.

Eur J Anaesthesiol

University of Münster, Department of Anesthesiology and Intensive Care, Münster, Germany.

Published: February 2003

Background And Objective: Stable drug concentrations must be administered to provide adequate patient-controlled epidural analgesia. This study investigated the stability of sufentanil after the epidural delivery system had been flushed with solutions containing the drug.

Methods: Sufentanil citrate, 5 microg mL(-1) was injected through an epidural catheter system into a glass container. The concentrations of the drug leaving the system, in 1 mL aliquots (1-5 mL) were measured using high-performance liquid chromatography. In the same manner, sufentanil samples were analysed after flushing the filter, as well as after priming the filter and catheter.

Results: ANOVA for repeated measurements demonstrated that sufentanil concentrations remained constant as long as the catheter had been adequately flushed. However, the concentration of sufentanil in the solution exiting the filter was reduced significantly. Hardly any sufentanil could be detected (0.09 +/- 0.01 microg mL(-1), P < 0.001) in the first 1 mL aliquot (probe) leaving the filter. Altogether, 3 mL sufentanil solution was needed to pass through the filter before the baseline values were restored (P > 0.05). The greatest decrease occurred when the whole epidural delivery apparatus (catheter and filter) was primed; to regain baseline values, as much as 4 mL solution was needed to flush the system.

Conclusions: Sufentanil citrate is adsorbed by the materials used to manufacture systems (catheters, filters) used in epidural anaesthesia. Hence, the epidural catheter system should be primed with sufentanil before connecting it to the patient so as to deliver reliable concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1017/s0265021503000231DOI Listing

Publication Analysis

Top Keywords

sufentanil
9
sufentanil epidural
8
epidural delivery
8
sufentanil citrate
8
microg ml-1
8
epidural catheter
8
catheter system
8
sufentanil solution
8
solution needed
8
baseline values
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!