A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rare-earth glass reference materials for near-infrared spectrometry: correcting and exploiting temperature dependencies. | LitMetric

Rare-earth glass reference materials for near-infrared spectrometry: correcting and exploiting temperature dependencies.

Anal Chem

Analytical Chemistry Division, Chemical Science and Technology Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899-8394, USA.

Published: February 2003

Quantitative descriptions of the location of seven near-infrared absorption bands as functions of temperature 5-50 degrees C are presented here for three recently introduced wavelength/wavenumber Standard Reference Materials (SRMs): SRM 2035, SRM 2065, and SRM 2036. For all bands in all three SRMs, locations are well described as linear models parametrized with the location at 0 degrees C (intercept) and the rate of location change per degrees C (slope). Since these materials were produced from compositionally similar melts, the slopes for each band are identical within measurement imprecision in all three SRMs; only minor differences are observed in the intercepts. Because the direction of change in location differs among the bands, it is possible to use the measured band locations to reliably estimate sample temperature. Two approaches to estimating temperature are evaluated: slope and measurement uncertainty-weighted means. While both methods work well with measurements made under well-characterized and stable environmental conditions, the more complex uncertainty-weighted analysis becomes relatively more predictive as the total measurement uncertainties increase.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac025969fDOI Listing

Publication Analysis

Top Keywords

reference materials
8
three srms
8
rare-earth glass
4
glass reference
4
materials near-infrared
4
near-infrared spectrometry
4
spectrometry correcting
4
correcting exploiting
4
temperature
4
exploiting temperature
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!