A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrogenerated chemiluminescence derivatization reagent, 3-isobutyl-9,10-dimethoxy-1,3,4,6,7,11b-hexahydro-2H-pyrido[2,1-a]isoquinolin-2-ylamine, for carboxylic acid in high-performance liquid chromatography using tris(2,2'-bipyridine)ruthenium(II). | LitMetric

3-Isobutyl-9,10-dimethoxy-1,3,4,6,7,11b-hexahydro-2H-pyrido[2,1-a]isoquinolin-2-ylamine (IDHPIA) was found to be a selective and highly sensitive derivatization reagent for carboxylic acid by high-performance liquid chromatography (HPLC) with electrogenerated chemiluminescence detection using tris(2,2'-bipyridine)ruthenium(II). Free fatty acids and phenylbutylic acid were used as model compounds of carboxylic acids, and the derivatization conditions were optimized with myristic acid. Under the mild reaction conditions of room temperature for 45 min in acetonitrile containing 2-bromo-1-ethylpyridinium tetrafluoroborate and 9-methyl-3,4-dihydro-2H-pyridol1,2-a]pyrimidin-2-one, all the fatty acids tested were reacted with IDHPIA to produce highly sensitive derivatives. The chemiluminescence intensity was essentially the same for all fatty acids. The derivatives obtained from 10 free fatty acids were completely separated by reversed-phase chromatography under isocratic elution conditions. The on-column detection limit (signal-to-noise ratio of 3) with proposed HPLC separation and chemiluminescence detection was 0.5 and 0.6 fmol for myristic acid and phenylbutylic acid, respectively. IDHPIA was 100-fold more sensitive than previously developed reagents (Morita, H.; Konishi, M. AnaL Chem. 2002, 74, 1584-1589). The free fatty acids in human serum were successfully determined using the present method.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac020377iDOI Listing

Publication Analysis

Top Keywords

fatty acids
20
free fatty
12
electrogenerated chemiluminescence
8
derivatization reagent
8
carboxylic acid
8
acid high-performance
8
high-performance liquid
8
liquid chromatography
8
highly sensitive
8
chemiluminescence detection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!