A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Variability of area measurements obtained with different intravascular ultrasound catheter systems: Impact on clinical trials and a method for accurate calibration. | LitMetric

Background: Atherosclerotic plaque burden is the major end point in ongoing progression trials. Intravascular ultrasound allows precise measurements of coronary artery dimensions. However, the variability of measurements among different catheter systems is incompletely characterized.

Methods: Intravascular ultrasound imaging was performed in a cylindric phantom with 5 sections of different, known, cross-sectional area ranging from 3.24 to 27.99 mm(2). A total of 3637 measurements with different catheter systems (Atlantis SR and Ultracross, Scimed/Boston Scientific; and Invision and Avanar, Jomed) were performed. Measurements were divided into model building and validation datasets. For each catheter, calibration models were developed.

Results: Overestimation and underestimation of the true cross-sectional area of up to 18% was observed with different catheter systems. Calibration equations for the different systems could be developed that predicted the true diameter and area with high statistical precision (adjusted R(2) > 0.99).

Conclusions: Area measurements vary among different intravascular ultrasound catheter systems. Calibration equations can correct for these differences and allow the comparison of measurements among catheters.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mje.2003.45DOI Listing

Publication Analysis

Top Keywords

catheter systems
20
intravascular ultrasound
16
area measurements
8
ultrasound catheter
8
measurements catheter
8
cross-sectional area
8
systems calibration
8
calibration equations
8
measurements
7
catheter
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!