Purpose: To evaluate the accuracy of air displacement plethysmography (ADP) by using the BOD POD in comparison with hydrostatic weighing (HW) in a collegiate wrestling population in hydrated and acutely dehydrated states.

Methods: Body composition was determined by ADP, HW, and three-site skinfolds (SK) in 66 NCAA Division I collegiate wrestlers before and after acute dehydration (2.6% reduction in body mass). For all methods, body density (D(b)) was converted to percent body fat (%BF) by using the Brozek equation for Euro-Americans and the Schutte equation for African-Americans.

Results: There were no significant differences between ADP and HW for D(b), %BF, and fat-free mass (FFM) in either the hydrated or dehydrated states. The standard errors of the estimate for %BF estimated from ADP with HW as the reference method were 2.12% (hydrated) and 2.16% (dehydrated); prediction errors were 2.35% (hydrated) and 2.49% (dehydrated). Bland-Altman plots of D(b) and %BF showed no systematic bias, and 64 out 66 subjects fell within the 95% limits of agreement (mean difference +/- 2 SD) for both variables. For SK, %BF was significantly higher than HW in both the hydrated and dehydrated state. All methods (ADP, HW, and SK) showed a significant decrease in FFM from the hydrated to the dehydrated state.

Conclusions: This study demonstrates that the BOD POD air displacement method provides similar estimates of D (b), %BF, and FFM when compared with HW in a heterogeneous collegiate wrestling population during hydrated and acutely dehydrated states. Pretest guidelines to ensure normal hydration status before body composition assessment using any method must be followed to minimize measurement error in %BF.

Download full-text PDF

Source
http://dx.doi.org/10.1249/01.MSS.0000053726.16625.D5DOI Listing

Publication Analysis

Top Keywords

air displacement
12
body composition
12
hydrated dehydrated
12
collegiate wrestlers
8
bod pod
8
collegiate wrestling
8
wrestling population
8
population hydrated
8
hydrated acutely
8
acutely dehydrated
8

Similar Publications

Magnetotransport of conventional semiconductor based double layer systems with barrier suppressed interlayer tunneling has been a rewarding subject due to the emergence of an interlayer coherent state that behaves as an excitonic superfluid. Large angle twisted bilayer graphene offers unprecedented strong interlayer Coulomb interaction, since both layer thickness and layer spacing are of atomic scale and a barrier is no more needed as the twist induced momentum mismatch suppresses tunneling. The extra valley degree of freedom also adds richness.

View Article and Find Full Text PDF

Introduction: For preterm infants, the first two weeks after birth are a time when nutrition and protein intake is variable and often falls below recommended intakes. Our objective was to investigate the relationship between protein intake, including source of protein, during the first two weeks after birth and fat-free mass (FFM) accretion in a group of very preterm infants.

Methods: In this observational cohort study, body composition was assessed using air displacement plethysmography in eligible infants <32 weeks gestational age at two weeks after birth and prior to discharge.

View Article and Find Full Text PDF

Climate change represents an unprecedented global public health crisis with extensive and profound implications. The Lancet Commission identified it as the foremost health challenge of the 21st century. In 2015, air pollution alone caused approximately 9 million premature deaths worldwide.

View Article and Find Full Text PDF

Background: The body composition of National Collegiate Athletic Association (NCAA) athletes is well documented but no such data exist for university club sports athletes. Additionally, the majority of norms for NCAA athletes were created from individual methods requiring assumptions.

Objective: This study used a four-component (4C) model to measure the body composition of university club sports athletes.

View Article and Find Full Text PDF

Pneumothorax, a life-threatening condition characterized by air accumulation in the pleural cavity, requires early and accurate detection for optimal patient outcomes. Chest X-ray radiographs are a common diagnostic tool due to their speed and affordability. However, detecting pneumothorax can be challenging for radiologists because the sole visual indicator is often a thin displaced pleural line.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!