An approach for the replacement of the distal ascending aorta-proximal arch and acute dissection is described. During the operation, the patient's entire body was continuously perfused, the aortic arch was excluded from the arterial circulation, and the aorta was not clamped at any time. To achieve continuous body perfusion, we independently cannulated the right axillary and the left femoral arteries. The right atrium was cannulated for systemic venous return, and the right radial artery was used for arterial blood pressure monitoring. The myocardium was protected with retrograde cardioplegia, and the body was protected with moderate hypothermia. Vascular clamps were placed to the proximal innominate, left carotid, and left subclavian arteries without discontinuing perfusion of the right axillary artery. A temporary clamp was applied to the femoral line, the aorta was transected, and a large Foley catheter was inserted through the true aortic lumen. The Foley bulb was positioned in the proximal descending thoracic aorta and distended with saline until the aortic blood return ceased. The femoral line clamp was removed from the cannula, and the entire body was perfused during the completion of the distal aortic anastomosis. At the completion of the anastomosis, the Foley bulb was slightly deflated. Once the inserted graft was filled with blood, a large vascular clamp was applied to the graft, and the previously placed clamps were removed from the arch branches. The femoral line was removed, and the body was perfused and rewarmed via the axillary cannulation. Following completion of the proximal graft-aortic anastomosis, the heart was reperfused, and all cannulas were removed in the usual fashion. Rapid recovery characterized the patient's initial postoperative course; however, multiple organ failure secondary to pump-induced inflammatory response followed. Aggressive medical management resulted in complete patient recovery. No neurologic deficits were observed, and the patient regained full cognitive function. This report describes a simple approach to facilitate repair of the aortic arch and minimize postoperative organ failure.

Download full-text PDF

Source
http://dx.doi.org/10.1532/hsf.552DOI Listing

Publication Analysis

Top Keywords

continuous body
8
body perfusion
8
entire body
8
aortic arch
8
clamp applied
8
foley bulb
8
body perfused
8
organ failure
8
body
6
aortic
5

Similar Publications

Background: Gallbladder and biliary tract cancers (GBTCs) are aggressive with poor prognosis, often undetected until advanced stages. High Body Mass Index (BMI) is a significant risk factor, contributing substantially to GBTC mortality and Disability-Adjusted Life Years (DALYs). This study aimed to quantify the global burdens of GBTCs attributable to high BMI from 1990 to 2021, thereby developing more rational prevention and treatment strategies for GBTC.

View Article and Find Full Text PDF

Anterior cord syndrome is a rare yet critical neurological condition that poses significant challenges in clinical management. We present the case of a 71-year-old male with a medical history of hypertension, uncontrolled type II diabetes mellitus, hypothyroidism, and end-stage renal disease requiring dialysis who presented to the emergency department with complaints of chills, back pain, abdominal pain, and vomiting episodes. Based on the severity of the patient's illness, it was decided that inpatient admission would be best.

View Article and Find Full Text PDF

Although the fractional polynomials (FPs) can act as a concise and accurate formula for examining smooth relationships between response and predictors, modelling conditional mean functions observes the partial view of a distribution of response variable, as distributions of many response variables such as blood pressure (BP) measures are typically skew. Conditional quantile functions with FPs provide a comprehensive relationship between the response variable and its predictors, such as median and extremely high-BP measures that may be often required in practical data analysis generally. To the best of our knowledge, this is new in the literature.

View Article and Find Full Text PDF

The French Agency for Food, Environmental and Occupational Health & Safety (Anses) has set up a multidisciplinary working group (WG) to develop an innovative One Health approach for the monitoring and evaluation of an integrated vector management system (IVMS) on a territorial scale. Four existing evaluation guidelines and methods have been combined into a semi-quantitative evaluation approach that takes into account all the dimensions of an integrated process. We propose a set of 34 criteria divided into three sections (objectives and management, implementation, integration) that correspond to the main functional components of an IVMS.

View Article and Find Full Text PDF

Baseline and cumulative Chinese visceral adiposity index and diabetic kidney disease: A prospective cohort study.

Diabetes Obes Metab

January 2025

Key Laboratory of Environmental Stress and Chronic Disease Control & Prevention, Ministry of Education, Department of Biostatistics and Epidemiology, School of Public Health, China Medical University, Shenyang, China.

Background: Diabetic kidney disease (DKD) makes up nearly half of all chronic kidney disease cases and is a major cause of mortality for people with diabetes. However, the study of the association of longitudinal Chinese visceral adiposity index (CVAI) with DKD is still missing.

Methods: This prospective cohort study included 7874 diabetes patients from the Kailuan study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!