A study of piezoelectric and mechanical anisotropies of the human cornea.

Biosens Bioelectron

Department of Chemical and Biochemical Engineering, Polymer Electroprocessing Laboratory, College of Engineering, Rutgers-The State University of New Jersey, 98 Brett Road, Piscataway, NJ 08854-8058, USA.

Published: April 2003

The piezoelectric and dynamic mechanical properties of human cornea have been investigated as a function of drying time. As expected, the piezoelectric coefficient, d(31), and the Young's modulus, Y, were found to be extremely sensitive to water content. d(31) decreased with dehydration of the corneal tissue and Y increased with dehydration. While these results are significant, the discovery of the unprecedented mechanical and electromechanical anisotropy exhibited by the cornea are the major findings of this study and indicate that the collagen fibrils comprising the cornea are highly oriented. The piezoelectric responses of corneas observed in this study are: diagonally cut samples starting at an average piezoelectric coefficient value of 2250 pC/N, followed by the vertically cut samples, with an average starting value of about 600 pC/N and finally the horizontally cut samples with an average starting value of about 200 pC/N.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0956-5663(02)00144-6DOI Listing

Publication Analysis

Top Keywords

cut samples
12
human cornea
8
piezoelectric coefficient
8
samples average
8
average starting
8
study piezoelectric
4
piezoelectric mechanical
4
mechanical anisotropies
4
anisotropies human
4
cornea
4

Similar Publications

Utilization of refuse-derived fuel in industrial applications: Insights from Uttar Pradesh, India.

Heliyon

January 2025

Interdisciplinary Research Center for Construction and Building Materials, Research Institute, King Fahd University of Petroleum & Minerals, Dhahran, 31261, Saudi Arabia.

Urbanization and population growth in India have quickened, leading to an annual generation of around 62 million tonnes of municipal solid waste (MSW). Improper management of organic waste presents a major environmental problem due to air and water pollution, soil contamination and greenhouse gas production. This research aims to develop refuse-derived fuel (RDF) as a viable option, converting waste into a high-calorific energy carrier for industrial use.

View Article and Find Full Text PDF

Mitigating matrix effects in oil and gas wastewater analysis: LC-MS/MS method for ethanolamines.

Environ Sci Process Impacts

January 2025

Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, Parsons Laboratory, 15 Vassar Street, Cambridge, Massachusetts 02139, USA.

The high salinity and organic content in oil and gas wastewaters can cause ion suppression during liquid chromatography mass spectrometry (LC/MS) analysis, diminishing the sensitivity and accuracy of measurements in available methods. This suppression is severe for low molecular weight organic compounds such as ethanolamines (, monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), -methyldiethanolamine (MDEA), and ,-ethyldiethanolamine (EDEA)). Here, we deployed solid phase extraction (SPE), mixed-mode LC, triple quadrupole MS with positive electrospray ionization (ESI), and a suite of stable isotope standards (, one per target compound) to correct for ion suppression by salts and organic matter, SPE losses, and instrument variability.

View Article and Find Full Text PDF

Objectives: To evaluate the role of serum procalcitonin (PCT) as a diagnostic tool to differentiate bacterial sepsis from flare-ups during febrile episodes in children with known rheumatic disorders compared to other inflammatory markers like C-reactive protein (CRP), and erythrocyte sedimentation rate (ESR).

Methods: Previously diagnosed patients with known rheumatic disorders presenting in emergency or outpatient departments with febrile episodes were included in the study. Blood samples were collected upon admission to test for signs of infection, including serum PCT levels with routine laboratory and radiological tests.

View Article and Find Full Text PDF

Objective: Infants are at a high risk of developing anaemia, which can arise from various causes, including inappropriate feeding practices. However, few infants attend anaemia screening programmes due to poor cooperation and being time-consuming. This study evaluated the accuracy of noninvasive total haemoglobin (Hb) spot-check monitoring as part of anaemia screening in healthy infants, compared with the conventional laboratory method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!