Continuous electrochemical treatment of phenolic wastewater in a tubular reactor.

Water Res

Faculty of Engineering, Chemical Engineering Department, Hacettepe University, Beytepe 06532, Ankara, Turkey.

Published: April 2003

AI Article Synopsis

  • The study investigates a novel electrochemical method for treating phenolic wastewater using a continuous tubular reactor made of stainless steel and a carbon anode.
  • The research examines how varying residence time affects the removal of phenols at different concentrations, finding that higher residence times significantly improve the degradation efficiency.
  • Over 95% of the initial phenol was successfully converted into a non-hazardous polymer through a safe and energy-efficient process, highlighting the promising potential of this treatment method.

Article Abstract

The electrochemical treatment of phenolic wastewater in a continuous tubular reactor, constructed from a stainless steel tube with a cylindrical carbon anode at the centre, was investigated in this study, being first in literature. The effects of residence time on phenol removal was studied at 25 degrees C, 120 g l(-1) electrolyte concentration for 450 and 3100 mg l(-1) phenol feed concentrations with 61.4 and 54.7 mA cm(-2) current densities, respectively. The change in phenol concentration and pH of the reaction medium was monitored in every run and GC/MS analyses were performed to determine the fate of intermediate products formed during the electrochemical reaction in a specified batch run. During the electrolysis mono, di- and tri-substituted chlorinated phenol products were initially formed and consumed along with phenol thereafter mainly by polymerization mechanism. For 10 and 20 min of residence time phenol removal was 56% and 78%, respectively, with 450 mg l(-1) phenol feed concentration and above 40 min of residence time all phenol was consumed within the column. For 1, 1.5, 2 and 3h of residence time, phenol removal achieved was 42%, 71%, 81% and 98%, respectively, at 3100 mg l(-1) phenol feed concentration. It is noteworthy that more than 95% of the initial phenol was converted into a non-passivating polymer without hazardous end products in a comparatively fast and energy-efficient process, being a safe treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0043-1354(02)00523-7DOI Listing

Publication Analysis

Top Keywords

residence time
16
time phenol
16
phenol removal
12
l-1 phenol
12
phenol feed
12
phenol
11
electrochemical treatment
8
treatment phenolic
8
phenolic wastewater
8
tubular reactor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!