Background: This is a prospective study.

Method: . A total of 266 consecutive patients, who received 350 third-generation Zweymueller-SL total hip arthroplasties with metal-on-metal articulation for primary or secondary osteoarthritis, was followed and evaluated clinically, radiologically and histologically. The age of the patients at the time of surgery was 55+/-9 years, (range 25-70 years). Seven ( 3%) patients did not return for their last follow-up evaluation for reasons unrelated to their hip operation.

Results: The mean follow-up was 52 months (range 37-92 months). The preoperative Harris hip score was 45+/-19 and increased to 96+/-4 postoperatively. The invalidity of the patients was significantly improved postoperatively ( p<0.001). In all, 97% of the patients were satisfied or very satisfied with the result of the operation. There was no aseptic loosening noted in this series. Revision was done in 6 (1.8%) hips because of septic loosening ( n=5, 1.5%) or technical error ( n=1, 0.3%) during implantation. Dislocation of the prosthesis occurred in the early postoperative period in 2 (0.6%) hips. Periarticular ossification was observed in 30% of the hips (5% Brooker grades III and IV), but without associated disability. During revision surgery, no macroscopic metalosis could be identified in the newly formed hip joint membrane; however microscopic evidence for metalosis (Mirra grades 1 and 2) was seen in all revised hips. The survival for Zweymueller screw socket and stem 7.6 years after implantation was 99.4% and 96.8%, respectively.

Conclusions: This study showed that the short-term results of Zweymueller total hip arthroplasty with metal-on-metal articulation were just as satisfactory as those of a conventional polyethylene on ceramic articulation, while the metal-on-metal articulation does not seem to give rise to new problems or complications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-002-0456-xDOI Listing

Publication Analysis

Top Keywords

metal-on-metal articulation
8
zweymueller metal-on-metal
4
articulation clinical
4
clinical radiological
4
radiological histological
4
histological analysis
4
analysis short-term
4
short-term background
4
background prospective
4
prospective studymethod
4

Similar Publications

Background: While hip resurfacing arthroplasty has been shown to be an effective prosthetic solution for end-stage osteoarthritis, prior studies have also reported an increasing concern regarding blood metal ion levels following the use of metal-on-metal articulations. The purpose of this study was to compare early and midterm blood metal ion levels to functional outcomes and implant survivorship for patients treated with the Birmingham Hip Resurfacing (BHR) implant system and the ReCap Magnum.

Methods: A retrospective review identified 104 patients who underwent 134 hip resurfacing arthroplasties using BHR (n = 67) and ReCap (n = 67) at a single institution between 2006 and 2018.

View Article and Find Full Text PDF

Introduction: Pseudotumors are well-known complications following total hip arthroplasty (THA), usually attributed to debris-induced inflammation from direct metal-on-metal contact between implants. In total knee arthroplasty (TKA), the traditional use of polyethylene as a bearing surface prevents direct metal articulation. Thus, pseudotumor formation in TKA usually suggests atypical metal interaction between the prosthetic components.

View Article and Find Full Text PDF

Explant analysis can provide important understanding of how artificial joints perform in the human body. The articulating surfaces of the metacarpal head and the radius cup from a chromium nitride coated metal-on-metal Motec wrist implant were analysed. Due to bone resorption and aseptic loosening, the implant was removed after 6 years in the patient, and metallosis was observed during removal.

View Article and Find Full Text PDF
Article Synopsis
  • Metallosis can occur not just in Metal-on-Metal (MoM) hip replacements, but also in metal-on-polyethylene (PE) articulations, making diagnosis challenging.
  • A case study of a 35-year-old woman showed that after experiencing recurrent dislocation four years post-surgery, intraoperative metallosis was confirmed during revision surgery after changes to her hip implant.
  • Early detection of metallosis is crucial, as subtle signs can easily be overlooked, and prompt treatment can prevent further complications like osteolysis and soft tissue damage.
View Article and Find Full Text PDF

Metal hypersensitivity is a rare and often underestimated complication, as shown by the small number of published studies, particularly concerning the upper limbs and the hand. However, the increase in the annual number of trapeziometacarpal arthroplasties underlines the importance of better understanding of this problem. We performed a study based on data from the revision of trapeziometacarpal prostheses to assess the incidence of this complication and to define a sequence of radiological changes to detect metal hypersensitivity.