The treatment of both the bronchoconstriction and inflammatory aspects of asthma simultaneously by a single pressurized metered dose inhaler (pMDI) represents a significant advance in convenience to the patient. However, a valved holding chamber (VHC) may still be needed to reduce the coarse component of the dose that is likely to deposit in the oropharyngeal region, and a small sized device may offer significant advantages to the patient from the standpoint of compliance with therapy. VHCs representing small (adult AeroChamber Plus with mouthpiece, 149-mL) and large (Volumatic, 750-mL) devices have been compared in an in vitro evaluation with Seretide/Advair (hydro-fluoro alkane [HFA]-formulated fluticasone propionate [FP = 125 microg/dose] and salmeterol xinafoate [SX = 25 microg/dose]) by Andersen Mark-II eight-stage impactor operated at 28.3 L/min following compendial methodology. Fine particle fraction, based on the size range from 1.1 to 4.7 microm aerodynamic diameter, from either large or small VHCs with either component (69-79%) was similar [p > or = 0.08], and significantly greater than that from the pMDI alone (approximately 40%) [p < 0.001]. Fine particle dose emitted by the VHCs for SX (8.2 +/- 0.8 microg for the AeroChamber Plus and 7.7 +/- 0.5 microg for the Volumatic) were comparable, and also similar to the fine particle dose delivered by the pMDI when used without a VHC (7.6 +/- 0.6 microg). Fine particle doses for the FP component delivered by the two VHCs (46.4 +/- 3.4 microg for the AeroChamber Plus and 46.3 +/- 2.7 microg for the Volumatic) were equivalent, but were slightly greater than the corresponding fine particle dose from the pMDI alone (39.1 +/- 2.6 microg). However, this difference (approximately 20%) is close to the limit of resolution based on intermeasurement variability and is unlikely to have clinical significance, given the interpatient variability seen with inhaled drug therapy. It is therefore concluded that either of these VHCs has equivalent in vitro performance with this combination formulation in terms of the portion of the dose emitted from the pMDI that is likely to reach the receptors in the lungs.

Download full-text PDF

Source
http://dx.doi.org/10.1089/08942680260473506DOI Listing

Publication Analysis

Top Keywords

+/- microg
24
fine particle
20
particle dose
12
valved holding
8
pressurized metered
8
metered dose
8
dose inhaler
8
dose emitted
8
microg aerochamber
8
microg volumatic
8

Similar Publications

Effects of gravity, microgravity or microgravity simulation on early mouse embryogenesis: A review of the first two space embryo studies.

Mechanobiol Med

December 2024

C. S. Mott Center for Human Health and Development, Department of Obstetrics and Gynecology, Wayne State University, Detroit, MI, United States.

Many simulated micro-gravity (micro-G) experiments on earth suggest that micro-G conditions are not compatible with early mammalian embryo development. Recently, the first two "space embryo" studies have been published showing that early mouse embryo development can occur in real microgravity (real micro-G) conditions in orbit. In the first of these studies, published in 2020, Lei and collaborators developed automated mini-incubator (AMI) devices for mouse embryos facilitating cultivation, microscopic observation, and fixation.

View Article and Find Full Text PDF

This study investigates food odour perception and affective response within a virtually simulated spacecraft environment, with links to the volatile composition of odours. Healthy participants (n = 44) between the ages of 18-39 years rated the intensity of eight food odours in two simulated space environments for comparison, a 'microgravity' posture (MicroG Posture; physical) and Virtual Reality (VR; visual-spatial cues) simulation of a spacecraft. Results indicate that these methods yield different outcomes.

View Article and Find Full Text PDF

Background: The aim of this study was to validate in 20-year follow-up (FU) the outcomes reported in World J Surg 2010; 34(6):1232-8 on recurrent nodular goiter in the contralateral thyroid lobe among patients after thyroid lobectomy (TL) for multinodular goiter (MNG) receiving versus not receiving postoperative prophylactic levothyroxine (LT4) treatment.

Methods: Some 150 consenting patients underwent TL for MNG in 2000-2003. They were randomized to two groups, 75 patients each: (a) receiving prophylactic LT4 treatment postoperatively (dose range 75-125 microg/day to maintain thyroid-stimulating hormone values within 0.

View Article and Find Full Text PDF

G protein-coupled estrogen receptor 1 (GPER-1) has gained recognition for its role in conferring cardioprotection. However, the extent to which GPER-1 exerts equally important effects in both sexes remains unclear. The study found similar expressions of GPER-1 in rat heart apex in both sexes.

View Article and Find Full Text PDF
Article Synopsis
  • * The X-ray process enhances mercury oxidation by producing electrons, while an electric field directs oxidized mercury to bond with the nanofiber mat.
  • * The study found that the process captures mercury in two ways: chemically (0.2 to 10 ng in total) and on the surface of the fibers (10 microg/m per minute), providing a promising solution to reduce emissions from coal power plants.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!