Objectives: Our aim was to validate 3-dimensional echocardiography (3DE) for assessment of left ventricular (LV) end-diastolic volume, end-systolic volume (ESV), stroke volume, and ejection fraction (EF) using the freehand-acquisition method. Furthermore, LV volumes by breath hold-versus free breathing-3DE acquisition were assessed and compared with magnetic resonance imaging (MRI).

Methods: From the apical position, a fan-like 3DE image was acquired during free breathing and another, thereafter, during breath hold. In 27 patients, 28 breath hold- and 24 free breathing-3DE images were acquired. A total of 17 patients underwent both MRI and 3DE. MRI contours were traced along the outer endocardial contour, including trabeculae, and along the inner endocardial contour, excluding trabeculae, from the LV volume.

Results: All 28 (100%) breath hold- and 86% of free breathing-3DE acquisitions could be analyzed. Intraobserver variation (percentual bias +/- 2 SD) of end-diastolic volume, ESV, stroke volume, and EF for breath-hold 3DE was, respectively, 0.3 +/- 10.2%, 0.3 +/- 14.6%, 0.1 +/- 18.4%, and -0.1 +/- 5.8%. For free-breathing 3DE, findings were similar. A significantly better interobserver variability, however, was observed for breath-hold 3DE for ESV and EF. Comparison of breath-hold 3DE with MRI inner contour showed for end-diastolic volume, ESV, stroke volume, and EF, a percentual bias (+/- 2 SD) of, respectively, -13.5 +/- 26.9%, -17.7 +/- 47.8%, -10.6 +/- 43.6%, and -1.8 +/- 11.6%. Compared with the MRI outer contour, a significantly greater difference was observed, except for EF.

Conclusions: 3DE using the freehand method is fast and highly reproducible for (serial) LV volume and EF measurement, and, hence, ideally suited for clinical decision making and trials. Breath-hold 3DE is superior to free-breathing 3DE regarding image quality and reproducibility. Compared with MRI, 3DE underestimates LV volumes, but not EF, which is mainly explained by differences in endocardial contour tracing by MRI (outer contour) and 3DE (inner contour) of the trabecularized endocardium. Underestimation is reduced when breath-hold 3DE is compared with inner contour analysis of the MRI dataset.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mje.2003.7DOI Listing

Publication Analysis

Top Keywords

breath-hold 3de
20
3de
13
end-diastolic volume
12
volume esv
12
esv stroke
12
stroke volume
12
free breathing-3de
12
endocardial contour
12
inner contour
12
+/-
10

Similar Publications

Recent guidelines regard three-dimensional echocardiography (DE) derived measurements of left ventricular (LV) volumes and ejection fraction (EF) as the method of choice. The feasibility of 3DE and agreement between 2DE and 3DE was examined. Our hypothesis was that a number of patients can only be examined with 2DE in a patient population admitted to a general hospital.

View Article and Find Full Text PDF

Background: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF.

View Article and Find Full Text PDF

Reconstructed versus real-time 3-dimensional echocardiography: comparison with magnetic resonance imaging.

J Am Soc Echocardiogr

July 2007

University of Queensland, Department of Medicine, Princess Alexandra Hospital, Ipswich Road, Brisbane, Q4102, Australia.

Background: The accuracy, reproducibility, and test-retest reliability of 3-dimensional (3D) echocardiography (3DE) with 3D reconstruction (3DR) and real-time (RT) imaging (RT 3DE) exceed that of 2-dimensional echocardiography (2DE). However, image quality with RT 3DE is inferior to 2DE and we sought to determine whether this justified ongoing use of 3DR.

Methods: Unselected patients (n = 30, 22 men, age 66 +/- 7 years) presenting to the echocardiography laboratory for left ventricular (LV) evaluation were studied with 2DE and RT 3DE; 3DR images were obtained using external localization.

View Article and Find Full Text PDF

Echocardiographic follow-up of left ventricular (LV) volumes is difficult because of the test-retest variation of 2-dimensional echocardiography (2DE). We investigated whether the accuracy and reproducibility of real-time 3-dimensional echocardiography (RT3DE) would make this modality more feasible for serial follow-up of LV measurements. We performed 2DE and RT3DE and cardiac magnetic resonance imaging (MRI) in 50 patients with previous infarction and varying degrees of LV function (44 men; 61 +/- 11 years of age) at baseline and after 1-year follow-up.

View Article and Find Full Text PDF

Background: The availability of automated online software may increase the feasibility of real-time 3-dimensional (3D) echocardiography (3DE) for left ventricular (LV) volume calculation in clinical practice. We sought to compare offline and online approaches with magnetic resonance imaging (MRI).

Methods: Patients who presented to the clinical laboratory for evaluation of LV parameters (n = 110, 94 men, age 63 +/- 10 years) were studied with 2-dimensional echocardiography, online and offline 3DE, and MRI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!