Novel normal-phase gradient systems have been employed for fast high-throughput chiral analyses of Discovery compounds in our research laboratories in Eli Lilly and Company. In this report, we describe an automated screening approach based on gradient elution, in order to achieve accurate enantiomeric excess determinations, and chiral separations when needed, in the shortest possible timeframe. Baseline resolution of enantiomers has been obtained for over 85% of the samples so tested. For the remaining cases, complete enantioseparation by isocratic optimisation is generally achieved in a single shot. This technique has been proven to be robust and is now standard operating procedure at our analytical research laboratories.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0021-9673(02)01735-1 | DOI Listing |
J Chromatogr A
August 2024
Van't Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam, Science Park 904, 1098 XH Amsterdam, the Netherlands. Electronic address:
End groups of poly(Lactide-co-glycolide) (PLGA) play an important role in determining the properties of polymers for use in drug delivery systems. For instance, it has been reported that the encapsulation efficiency in PLGA microspheres varies significantly between ester-terminated and acid-terminated PLGA. More importantly, the in-vivo degradation time of such polymer excipients is influenced by the functional end-group of the copolymer used.
View Article and Find Full Text PDFJ Chromatogr A
March 2024
Department of Analytical and Material Science, BASF SE, Carl-Bosch-Straße 38, Ludwigshafen am Rhein 67056, Germany. Electronic address:
The separation of vitamin A acetate isomers is essential for quality assurance of e.g. nutrition supplements, cosmetics, and pharmaceutical ingredients.
View Article and Find Full Text PDFJ Chromatogr A
September 2023
Shaanxi Key Laboratory of Natural Products & Chemical Biology, College of Chemistry & Pharmacy, Northwest A&F University, 22 Xiong Road, Yangling 712100, Shaanxi, China. Electronic address:
In this study, a multi-dimensional chromatography system was developed by integrating normal-phase flash chromatography and counter-current chromatography to isolate flavonoids, phenylpropanoids, and thymol from the aerial parts of Thymus quinquecostatus Celak. In the online multi-dimensional switching system, a normal-phase flash chromatograph packed with 1.2 g of dry homogeneous silica gel mixture (containing 600 mg of methanol extract) was connected to counter-current chromatography via a six-port valve.
View Article and Find Full Text PDFJ Chromatogr A
August 2023
Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409-1061, USA. Electronic address:
Changes in the expression of glycan isomers have been implicated in the development and progression of several diseases. However, the analysis of structurally diverse isomeric N-glycans by LC-MS/MS is still a major analytical challenge, particularly due to their large number of possible isomeric conformations. Common approaches derivatized the N-glycans to increase their hydrophobicity and to gain better detection in the MS system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!