The purpose of the study was to evaluate the trauma induced by insertion of the linear microdialysis probe in the subcutaneous and dermal tissue in the rat and to check if the microdialysis probe insertion affects transdermal drug delivery. Non-invasive bioengineering methods (TEWL, Laser Doppler Velocimeter, Chromameter) as well as histology were combined to characterize these effects. The results showed that the dermal and subcutaneous insertion of microdialysis probes did not change skin permeability, blood flow and color, confirming the safety of this technique. The probe depth did not influence the trauma. No significant physical damage after probe insertion was noticed. Thus, the present work validates the use of microdialysis in dermatopharmacokinetics studies after topical or systemic drug delivery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000068290 | DOI Listing |
Front Pharmacol
January 2025
Center for Pharmacometrics and System Pharmacology, College of Pharmacy, University of Florida, Orlando, FL, United States.
Introduction: This study evaluated the relationship between total plasma and free kidney concentrations of amphotericin B (AmB) in healthy and -infected Wistar rats using microdialysis and has the potential to significantly impact future research in this field and promote the development of antifungal drugs. The findings of this study, which show that plasma levels are a good predictor for AmB kidney concentrations and can be used to optimize its dosing regimen, underscore the importance of this research.
Methods: Microdialysis probe recovery rates were determined by dialysis and retrodialysis , as well as by retrodialysis .
J Neurosci Methods
March 2025
Cognitive Neuroscience Laboratory, German Primate Center - Leibniz Institute for Primate Research, Goettingen, Germany; Faculty of Biology and Psychology, University of Goettingen, Goettingen 37077 Germany.
Background: Neuronal activity is modulated by behavior and cognitive processes. The combination of several neurotransmitter systems, acting directly or indirectly on specific populations of neurons, underlie such modulations. Most studies with non-human primates (NHPs) fail to capture this complexity, partly due to the lack of adequate methods for reliably and simultaneously measuring a broad spectrum of neurotransmitters while the animal engages in behavioral tasks.
View Article and Find Full Text PDFCrit Care
December 2024
Department of Intensive Care, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium.
Background: Intracranial multimodal monitoring (iMMM) is increasingly used in neurocritical care, but a lack of standardization hinders its evidence-based development. Here, we devised core outcome sets (COS) and reporting guidelines to harmonize iMMM practices and research.
Methods: An open, decentralized, three-round Delphi consensus study involved experts between December 2023 and June 2024.
Food Chem
February 2025
Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czechia. Electronic address:
A tubular microdialysis probe is made from polysulfone hollow fibre for human haemodialysis, which has an inner diameter of 200 μm and a thickness of 20 μm. Milk is deposited to the outer surface of the hollow fibre and allowed to dry to form a dry sample. The tubular probe is then connected to the syringe pump and microdialysis of the dry sample into 0.
View Article and Find Full Text PDFMol Pharm
November 2024
Department of Pharmacokinetics, Faculty of Pharmaceutical Sciences, Doshisha Women's College of Liberal Arts, Kyotanabe, Kyoto 610-0395, Japan.
Pharmacokinetic (PK) elucidation of polymeric micelles delivering anticancer drugs is crucial for accurate antitumor PK-pharmacodynamic (PK-PD) simulations. Particularly, establishing a methodology to quantify the tumor inflow and outflow of anticancer drugs encapsulated in polymeric micelles is an essential challenge. General tumor biodistribution experiments are disadvantageous in that inflow quantification is easy, but outflow quantification is challenging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!