Two new methods for the determination of dithiocarbamate pesticides in occupational hygiene sampling devices are described. Dithiocarbamate spiked occupational hygiene sampling devices, consisting of glass fibre (GF/A) filters, cotton pads, cotton gloves and disposable overalls, were reduced under acidic conditions and the CS2 evolved as a decomposition product was extracted into isooctane. The isooctane was then analysed using gas chromatography with mass spectrometry, for CS2, which provided a quantitative result for dithiocarbamates. Recoveries obtained were generally within a 70-110% range and reproducibilities better than 15% RSD were typically achieved. The method has been successfully applied to samples collected during occupational exposure surveys. A second method employing automatic thermal desorption-gas chromatography-mass spectrometry (ATD-GC-MS) has also been developed and applied to the direct analysis of GF/A (airborne) samples. The method relies on the thermal degradation of dithiocarbamates to release CS2, which is used to quantify the analytes. Thiram spiked GF/A filters gave an average recovery of 107% with an RSD of 4%. The performance of the two analytical methods were directly compared by analysing sub-portions of GF/A filters collected during a survey to evaluate occupational exposures to thiram during seed treatment operations. Both methods performed well for the analysis of airborne (GF/A) samples and produced results in good agreement. ATD-GC-MS is the preferred method for studies involving GF/A (airborne) samples only. Because of the wider applicability of the isooctane method for other sampling devices, it is the preferred choice when carrying out surveys which require a dermal as well as respirable exposure assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0021-9673(02)01771-5DOI Listing

Publication Analysis

Top Keywords

sampling devices
16
occupational hygiene
12
hygiene sampling
12
gf/a filters
12
determination dithiocarbamate
8
dithiocarbamate pesticides
8
pesticides occupational
8
isooctane method
8
automatic thermal
8
gf/a airborne
8

Similar Publications

Short-Time Preamplification-Assisted One-Pot CRISPR Nucleic Acid Detection Method with Portable Self-Heating Equipment for Point-of-Care Diagnosis.

Anal Chem

January 2025

State Key Laboratory for Manufacturing Systems Engineering, School of Instrument Science and Techonology, Xi'an Jiaotong University, Xi'an 710054, China.

Infectious diseases, especially respiratory infections, have been significant threats to human health. Therefore, it is essential to develop rapid, portable, and highly sensitive diagnostic methods for their control. Herein, a short-time preamplified, one-pot clustered regularly interspaced short palindromic repeats (CRISPR) nucleic acid detection method (SPOC) is developed by combining the rapid recombinase polymerase amplification (RPA) with CRISPR-Cas12a to reduce the mutual interference and achieve facile and rapid molecular diagnosis.

View Article and Find Full Text PDF

Behind the scenes of EQA-characteristics, capabilities, benefits and assets of external quality assessment (EQA).

Clin Chem Lab Med

January 2025

Canadian Microbiology Proficiency Testing Program (CMPT), Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.

The main stakeholders in external quality assessment (EQA) programs are the participants, in whose interests these challenges are ultimately organised. EQA schemes in the medical field contribute to improving the quality of patient care by evaluating the analytical and diagnostic quality of laboratory and point-of-care tests (POCT) by independent third parties and, if necessary, pointing out erroneous measurement results and analytical or diagnostic improvement potential. Other benefits include the option of using EQA samples for other important laboratory procedures, such as the verification or validation of diagnostic medical devices (IVD-MDs), a contribution to the estimation of measurement uncertainty, a means of training and educating laboratory staff through educational EQA programmes or samples, or even for independent and documented monitoring of staff competence, such as on samples with unusual or even exceptional characteristics.

View Article and Find Full Text PDF

Physical activity (PA) reduces the risk of negative mental and physical health outcomes in older adults. Traditionally, PA intensity is classified using METs, with 1 MET equal to 3.5 mL O·min·kg.

View Article and Find Full Text PDF

LC-HRMS screening procedure for the detection of 11 different classes of prohibited substances in dried urine spots for doping control purposes.

Anal Bioanal Chem

January 2025

Doping Control Laboratory, Department of Diagnostic Sciences, Ghent University, Block B, Ottergemsesteenweg 460, BE-9000, Ghent, Belgium.

Dried urine spots have recently been proposed as an alternative matrix in the anti-doping field. Drying urine may open the opportunity to limit microbial and thermal degradation of the prohibited substances during transportation to the anti-doping laboratories without the need for refrigeration or freezing. In this study, a multi-targeted initial testing procedure was developed for the determination of 237 prohibited drugs/metabolites from 11 different classes in dried urine spots.

View Article and Find Full Text PDF

Flow prediction in sound-based uroflowmetry.

Sci Rep

January 2025

Department of Signal Theory and Communications, Universidad de Valladolid, 47002, Valladolid, Spain.

Sound-based uroflowmetry (SU) offers a non-invasive alternative to traditional uroflowmetry (UF) for evaluating lower urinary tract dysfunctions, enabling home-based testing and reducing the need for clinic visits. This study compares SU and UF in estimating urine flow rate and voided volume in 50 male volunteers (aged 18-60), with UF results from a Minze uroflowmeter as the reference standard. Audio signals recorded during voiding were segmented and machine learning algorithms (gradient boosting, random forest, and support vector machine) estimated flow parameters from three devices: Ultramic384k, Mi A1 smartphone, and Oppo smartwatch.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!