Mechanical stresses in arterial walls are known to be implicated in the development of atherosclerosis. While shear stress and circumferential stress have received a lot of attention, axial stress has not. Yet, stenoses can be intuitively expected to produce a supplementary axial stress during flow systole in the region immediately proximal to the constriction cone. In this paper, a model for the estimation of this effect is presented, and ten numerical examples are computed. These examples show that the cyclic increase in axial stress can be quite considerable in severe stenoses (typically 120% or more of the normal stress value). This result is in best agreement with the known mechanical or morphological risk factors of stenosis progression and restenosis (hypertension, elevated pulse pressure, degree of stenosis, stenosis geometry, residual stenosis, etc). The supplementary axial stress generated by a stenosis might create the damages in the endothelium and in the elastic membranes which potentiate the action of the other risk factors (hyperlipidaemia, diabetes, etc). It could thus be an important cause of stenosis progression and of restenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/48/1/309DOI Listing

Publication Analysis

Top Keywords

axial stress
16
supplementary axial
12
stress
8
stress generated
8
risk factors
8
stenosis progression
8
progression restenosis
8
stenosis
7
axial
5
estimation supplementary
4

Similar Publications

Background: To compare the effect of minimally invasive and open transforaminal lumbar interbody fusion (TLIF) approaches in fusing the L4-L5 segment and predicting the potential risk of adjacent segment degeneration (ASD).

Methods: A computed tomography scan image was processed and the three-dimensional model of the L1-L5 spine was reconstructed. The minimally invasive and Open TLIF finite element models were constructed.

View Article and Find Full Text PDF

An investigation of the mechanism of adjacent segment disease in a porcine spine model.

Clin Biomech (Bristol)

January 2025

Department of Kinesiology and Physical Education, Wilfrid Laurier University, Waterloo, Ontario, Canada; Department of Health Sciences, Wilfrid Laurier University, Waterloo, Ontario, Canada. Electronic address:

Background: Fusion changes the biomechanics of the spine leading to the potential development of adjacent segment disease. Despite many studies on adjacent segment disease, it is largely unknown how spinal fixation affects the mechanical properties of the adjacent disc. The purpose of this study was to assess whether axial compression causes mechanical disruption to the annulus when the caudal spinal level is immobilized or injured.

View Article and Find Full Text PDF

The human body consists of many different soft biological tissues that exhibit diverse microstructures and functions and experience diverse loading conditions. Yet, under many conditions, the mechanical behaviour of these tissues can be described well with similar nonlinearly elastic or inelastic constitutive relations, both in health and some diseases. Such constitutive relations are essential for performing nonlinear stress analyses, which in turn are critical for understanding physiology, pathophysiology and even clinical interventions, including surgery.

View Article and Find Full Text PDF

This paper proposes a high-performance fiber optic interferometric hydrophone based on composite structure. Based on the air-backed push-pull fiber optic hydrophone structure, the inner elastic tube is replaced by a thick hollow column, introducing axial acoustic pressure sensing to improve the detection sensitivity of the fiber optic hydrophone. The influence of axial stress on the deformation of the composite structure is investigated by theoretical analysis and numerical simulation, and the structural design of fiber optic hydrophone with high acoustic pressure sensitivity and wide frequency response range is realized.

View Article and Find Full Text PDF

Anterior cervical interbody fusion (ACDF) has become a classic surgical procedure for the treatment of cervical degenerative diseases, and various interbody cages are widely used in this procedure. We used 3D printing technology to produce a new type of plate-locking cage, anticipating to achieve high fusion rate with the high biomechanical stability. This study is to compare the biomechanical characteristics between a newly designed interbody cage and a conventional Zero-profile cage during ACDF using finite element analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!