Cis-dichloroamine (4-amino-2, 2, 6, 6-tetramethylpiperidine-1-oxyl) platinum (II) (abbreviated to HJ5) is a novel platinum anticancer compound which has prospects for research and application. In order to establish a conventional analytical method, an HPLC has been studied. Under the conditions of acetonitrile-water (10:90, volume ratio) as mobile phase, detection wavelength of 210 nm, a Phenomenex column C18(150 mm x 3.9 mm i.d., 10 microns). The linear equation, recovery and accuracy of the method were determined with external standard method. The HPLC has satisfactory resolution between the peaks of HJ5 and impurities. The peak areas of HJ5 were linear to its amounts detected and the detection limit was 0.07 microgram. The hydration of HJ5 can be inhibited effectively by NaCl solution. In a 9 g/L NaCl solution, the stability can be kept for more than 2 hours which is enough for analysis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

novel platinum
8
platinum anticancer
8
anticancer compound
8
method hplc
8
nacl solution
8
hj5
5
[analysis novel
4
compound hj5
4
hj5 high
4
high performance
4

Similar Publications

and Beyond: Impact on Therapeutic Choices Across Cancer.

Cancers (Basel)

December 2024

Division of Medical Oncology, National Cancer Centre Singapore, 30 Hospital Blvd, Singapore 168583, Singapore.

Background: Identifying patients with gm is crucial to facilitate screening strategies, preventive measures and the usage of targeted therapeutics in their management. This review examines the evidence for the latest predictive and therapeutic approaches in -associated cancers.

Clinical Description: Data supports the use of adjuvant olaparib in patients with gm high-risk HER2-negative breast cancer.

View Article and Find Full Text PDF

Introduction: The treatment landscape of metastatic urothelial carcinoma (mUC) has evolved with the emergence of programmed cell death protein 1/ligand 1 (PD-1/L1) inhibitors. This study assessed mUC treatment patterns in Europe.

Methods: Data were derived from the Adelphi mUC Disease Specific Programme™ (November 2020 to April 2021), a large, cross-sectional, patient record-based survey of physicians in France, Germany, Italy, Spain, and the United Kingdom.

View Article and Find Full Text PDF

Fast response solid electrolyte oxygen sensors with porous thin film electrodes.

Rev Sci Instrum

January 2025

High Enthalpy Flow Diagnostics Group (HEFDiG), Institute of Space Systems, University of Stuttgart, Pfaffenwaldring 29, 70569 Stuttgart, Germany.

A novel solid electrolyte sensor with considerably improved response times is presented. The new so-called eFIPEX [etched flux (Φ) probe experiment] is based on the FIPEX [flux (Φ) probe experiment] sensor applied for the measurement of molecular and atomic oxygen concentrations. A main application is the measurement of atmospheric atomic oxygen aboard sounding rockets up to altitudes of 250 km.

View Article and Find Full Text PDF

Platinum resistance is a common cause of chemotherapy failure in lung adenocarcinoma (LUAD). Competing endogenous RNAs (ceRNAs), which function by competitively binding to miRNAs, can influence drug response. However, the regulatory mechanisms of ceRNAs underlying chemoresistance in LUAD remain largely unknown.

View Article and Find Full Text PDF

The synthesis and characterization of novel platinum(II) and platinum(IV) complexes derived from unsymmetrical ethylene or propylenediamine derivatives are presented. IR spectroscopy and ESI mass spectrometry techniques were employed to characterize the complexes, revealing distinctive absorption bands and isotope patterns. Furthermore, the complexes were characterized by H and C NMR spectroscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!