The EASI lead system, which is based on the dipole hypothesis of vectorcardiography, offers the possibility of deriving the standard 12-lead electrocardiogram (ECG) and other desired leads from ECGs recorded at only 4 sites; it uses the Frank E, A, and I electrode locations, a fourth electrode location (S) at the manubrium, and a reference electrode. Accordingly, the electrodes of this system can be applied rapidly on easy-to-locate, stable anatomical sites that leave the precordium free for other diagnostic procedures. In early EASI implementations, the derived leads differed from actual leads by more than some clinicians found acceptable. As these differences were thought to be caused by the fact that the coefficients that were used had been derived from a limited data set, we have calculated a new set of EASI coefficients for the standard 12 leads, and several other leads, by using a data set of 983 adult subjects with 120-lead ECGs and well-documented diagnoses. This database is a concatenation of 2 previously described ones: one consisting of 892 persons (normal subjects, postmyocardial-infarction patients with and without arrhythmias, and patients with ventricular arrhythmias but no history of myocardial infarction) and the other consisting of 91 patients with single-vessel coronary artery disease who underwent coronary balloon-inflation angioplasty. In addition to the coefficients for the standard 12 leads (derived for standard limb leads as well as for Mason-Likar leads), we derived coefficients for six additional unipolar leads (posterior V(7)-V(9), and right-sided V(3)R-V(5)R), the Frank orthogonal leads, and three bipolar, vessel-specific leads that have been previously shown to exhibit optimal sensitivity for acute myocardial ischemia. We also derived coefficients for the modified electrode locations of the EASI system that must be used with patients who have undergone a midline sternotomy. Optimal coefficients for lead transformations were determined by maximizing the ensemble average (over the entire data set) of the correlation between the derived and the true lead for the chosen interval of the averaged complex. For derived standard limb leads, the amplitude was adjusted to give the best root-mean-square fit over the entire PQRST interval, whereas for derived Mason-Likar leads it was adjusted to give the best ST-segment fit. The entire set of coefficients and their corresponding goodness-of-fit measures are presented.

Download full-text PDF

Source
http://dx.doi.org/10.1054/jelc.2002.37151DOI Listing

Publication Analysis

Top Keywords

leads
13
data set
12
coefficients
8
easi coefficients
8
electrode locations
8
derived
8
coefficients standard
8
standard leads
8
leads derived
8
derived standard
8

Similar Publications

Discovery of New Benzohydrazide Derivatives Containing 4-Aminoquinazoline as Effective Agricultural Fungicides, the Related Mechanistic Study, and Safety Assessment.

J Agric Food Chem

January 2025

State Key Laboratory of Green Pesticides, Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Center for Research and Development of Fine Chemicals, Guizhou University, Guiyang 550025, PR China.

A total of 38 new benzohydrazide derivatives bearing the 4-aminoquinazoline moiety were designed and synthesized based on the active subunit combination approach and tested in detail for their inhibition activities against eight agricultural phytopathogenic fungi. The bioassay results indicated that many of the synthesized compounds exhibited extraordinary fungicidal activities in vitro against the tested fungi. For example, compounds , , , and had EC (half-maximal effective concentration) values of 0.

View Article and Find Full Text PDF

Metallic Zn is a promising anode for high-safety, low-cost, and large-scale energy storage systems. However, it is strongly hindered by unstable electrode/electrolyte interface issues, including zinc dendrite, corrosion, passivation, and hydrogen evolution reactions. In this work, an in situ interface protection strategy is established by turning the corrosion/passivation byproducts (zinc hydroxide sulfates, ZHSs) into a stable hybrid protection layer.

View Article and Find Full Text PDF

Tuberculosis remains a leading global health threat, exacerbated by the emergence of multi-drug-resistant strains. The search for novel therapeutic agents is critical in addressing this challenge. This review systematically summarizes the potential of oxadiazole derivatives as promising candidates in antimycobacterial drug discovery.

View Article and Find Full Text PDF

Small RNAs (sRNAs) are a class of molecules capable of perceiving environmental changes and exerting post-transcriptional regulation over target gene expression, thereby influencing bacterial virulence and host immune responses. is a pathogenic bacterium that poses a significant threat to aquatic animal health. However, the regulatory mechanisms of sRNAs in .

View Article and Find Full Text PDF

Centimeter-Sized CsPbBr Single-Crystal Films for Energy-Resolved Radiation Detection.

ACS Appl Mater Interfaces

January 2025

Beijing Key Laboratory of Construction-Tailorable Advanced Functional Materials and Green Applications Experimental Center of Advanced Materials, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.

Metal halide perovskites (MHPs) are promising materials for radiation detection. Compared with polycrystalline films, single crystals (SCs) have lower defect density, higher carrier mobility, and lifetime. However, the direct synthesis of MHP SCs for large-area flat panel imaging detectors remains challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!