Background: Cardiac positioning during off-pump coronary artery bypass (OPCAB) using deep pericardial sutures (DPS) typically results in some degree of hemodynamic compromise. We sought to determine whether cardiac positioning using an apical suction device was hemodynamically superior to DPS.

Methods: Five healthy pigs underwent sternotomy and instrumentation to measure right atrial (RA) pressure, left ventricular (LV) pressure and volume, and aortic pressure and flow. These variables were recorded at baseline, with simple attachment of the apical suction device (Xpose Access Device, Guidant, Inc.), and during exposure of the posterior descending artery (PDA) and obtuse marginal (OM) branches of the left circumflex artery using DPS and the apical suction device.

Results: Application of the apical suction device to the beating heart in neutral anatomic position did not result in any statistically significant change in hemodynamics compared to baseline except for a small decrease in RA pressure. DPS positioning resulted in statistically significant compromise in nearly all measured hemodynamic parameters, including cardiac output (-21% PDA, -30% OM), mean arterial pressure (-18% PDA, -26% OM), and stroke work (-31% PDA, -38% OM). In addition, LV end-diastolic pressure decreased (-59% PDA, -51% OM) while RA pressure increased (+17% PDA, +16% OM). Similar target exposure using the apical suction device resulted in near-baseline hemodynamics. The only statistically significant changes were a modest decrease in cardiac output (-18% OM) and RA pressure (-11% PDA).

Conclusion: DPS positioning significantly compromises hemodynamics due to reduced LV filling. The apical suction device provides good exposure with less hemodynamic compromise.

Download full-text PDF

Source

Publication Analysis

Top Keywords

apical suction
28
suction device
24
cardiac positioning
12
positioning apical
8
beating heart
8
hemodynamic compromise
8
pressure
8
dps positioning
8
cardiac output
8
apical
7

Similar Publications

Article Synopsis
  • This study analyzed the effectiveness of traditional irrigation methods using a specially designed positive pressure side-vented needle and various suction cannulas for treating mandibles with two root canals.
  • Micro-CT scans enabled detailed computational models to be created, allowing for the assessment of flow patterns, velocities, and pressures during irrigation.
  • Results indicated that using suction cannulas significantly enhanced fluid flow and wall shear stress in the complex root structures, especially in areas that conventional methods struggled to reach.
View Article and Find Full Text PDF

Failed Regenerative Endodontic Case Treated by Modified Aspiration-irrigation Technique and Apexification.

J Contemp Dent Pract

January 2024

Department of Endodontics, University Dental Hospital, King Abdulaziz University, Jeddah, Saudi Arabia.

Aim: This report addresses the management of a large persistent discharging lesion in an 11-year-old boy. The report describes the use of aspiration-irrigation technique for the management of immature necrotic tooth with persistent discharge after a failed regenerative procedure.

Background: Regenerative endodontics aim to provide an increase in root canal width, length, and in apical closure.

View Article and Find Full Text PDF

Evaluation of the Efficacy of Various Root Canal Irrigants on Removal of Smear Layer in Primary Teeth: A Comparative Study.

J Pharm Bioallied Sci

July 2023

Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia.

Aim: The aim of the current research was to appraise the effectiveness of different radicular canal irrigant solutions on the elimination of the smear layer in deciduous teeth.

Materials And Methods: A total of 60 fit deciduous teeth that were subjected to extraction for a variety of curative reasons were employed in this research. Every sample tooth was subjected to decoronation at the CEJ employing a carborundum disk.

View Article and Find Full Text PDF

Aim: The intraventricular pressure difference (IVPD) is the pressure difference in early diastole from the base to the apex of the ventricle. It is a useful marker for evaluating diastolic function because of its role as a suction force. This study investigated the changes in total and segmental IVPDs in normal fetuses throughout gestation to obtain normative data equations.

View Article and Find Full Text PDF

Development of mesothelioma is associated with asbestos exposure. Common presentations are with pleural-based plaques invading the chest wall and/or pleural effusion on chest imaging. The intent of this case report is to describe a rare presentation of mesothelioma, which presented atypically as a large tension pneumothorax.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!