Stereoacuity versus fixation disparity as indicators for vergence accuracy under prismatic stress.

Ophthalmic Physiol Opt

Abteilung Neuroophthalmologie und Schielbehandlung, Universitäts-Augenklinik Freiburg, Killianstr 5, 79106 Freiburg, Germany.

Published: January 2003

Background: Fixation disparity has been widely used as an indicator for vergence accuracy under prismatic stress. However, the targets used for measuring fixation disparity contain artificial features in that the fusional contours are thinned out. We considered that stereoacuity might be a preferable indicator of vergence accuracy, as stereo targets represent natural viewing conditions.

Methods: We measured fixation disparity with a computer adaptation of Ogle's test and stereoacuity with the automatic Freiburg Stereoacuity Test. Eight subjects were examined under increasing base-in and base-out prisms.

Results: The response of fixation disparity to prismatic stress revealed the curve types described by Ogle and Crone. All eight subjects reached a stereoscopic threshold below 10 arcsec. In seven subjects the stereoscopic threshold increased before double vision occurred.

Conclusion: Our data suggest that stereoacuity is suitable to assess the range of binocular vision under prismatic stress. As stereoacuity bears the advantage over fixation disparity in that it can be measured without introducing artificial viewing conditions, we suggest exploring whether stereoacuity under prismatic stress would be more meaningful in the work-up of asthenopic patients than is fixation disparity.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1475-1313.2003.00089.xDOI Listing

Publication Analysis

Top Keywords

fixation disparity
28
prismatic stress
20
vergence accuracy
12
accuracy prismatic
8
indicator vergence
8
stereoscopic threshold
8
stereoacuity
7
fixation
7
disparity
7
prismatic
5

Similar Publications

To investigate the pattern and threshold of physiological growth, defining as axial length (AL) elongation that results in little refraction progression, among Chinese children and teenagers, a total of 916 children aged between 7 and 18 years from a 6-year longitudinal cohort study were included for analysis. Ocular biometry, cycloplegic refraction and demographic data were obtained annually. Physiological growth was calculated based on myopic progression and Gullstrand eye model, respectively.

View Article and Find Full Text PDF

Objective: To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.

Methods: Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.

View Article and Find Full Text PDF

Barriers to Healthcare Access and Utilization Among Racial and Ethnic Minorities with Noninfectious Uveitis.

Ophthalmology

January 2025

Department of Ophthalmology & Vision Science, Tschannen Eye Institute, University of California, Davis, Sacramento, California, United States. Electronic address:

Objective: To investigate barriers to healthcare access and utilization among patients with noninfectious uveitis (NIU) across different racial and ethnic groups.

Design: Retrospective cross-sectional study.

Subjects: Participants diagnosed with chronic NIU in the nationwide All of Us Research Program.

View Article and Find Full Text PDF

Anterior cruciate ligament reconstruction aims to improve knee stability and range of motion. The AperFix system consists of polymer components, and fixed-loop fixation is an established endoscopic technique. Our aim in this study was to compare the long-term clinical and radiological results of AperFix and fixed-loop fixation and to prove that the long-term results of the AperFix fixation method are at least as good as those of the fixed loop device.

View Article and Find Full Text PDF

Binocular vision requires that the brain integrate information coming from each eye. These images are combined (fused) to generate a meaningful composite image. Differences between images, within a range, provide useful information about depth (stereopsis).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!