A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating the in vitro adhesive strength of biomaterials. Biosimulator for selective leak closure. | LitMetric

Aims: Surgical measures always involve problems of hemostasis and tissue management. Tissue sealing can be carried out in this case, with knowledge of the adhesive strength of liquid and fleece-bound sealing being of great clinical relevance. By employing a leak closure model, it has been possible to perform in vitro standardized technological-biomechanical experiments on a biomembrane mounted in a pressure chamber (biosimulator).

Findings: Liquid sealing (fibrin gluing: 4.1 hPa, photopolymerisate: 82.9 hPa) offers minimal and maximal adhesive strengths. Fleece-bound sealing does not depend on the carrier material and is always more stabile than pure liquid sealing, whereby systems that must be coated "on the spot" (prepare-to-use: 22.3-25.3 hPa) exhibit significantly lower adhesive strength (p < 0.0001) than a biodegradable collagen system, which is ready-to-use thanks to its fibrinogen-based coating (TachoComb H). Practicability, effectiveness and efficiency are further advantages of ready-to-use systems.

Conclusions: The biosimulator, presented here, is flexible in terms of its application for tissue management and it enables reproducible, economic and ecological evaluation of repair systems, e.g. tissue sealings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0142-9612(02)00522-7DOI Listing

Publication Analysis

Top Keywords

adhesive strength
12
leak closure
8
tissue management
8
fleece-bound sealing
8
liquid sealing
8
sealing
5
evaluating vitro
4
adhesive
4
vitro adhesive
4
strength biomaterials
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!