A contact lens as an artificial cornea for improved visualization during practice surgery on cadaver eyes.

Arch Ophthalmol

Department of Ophthalmology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA.

Published: January 2003

Objective: To describe the use of a polymethylmethacrylate contact lens as an artificial cornea to enhance visualization for practice surgery using cadaver eyes.

Design: The opaque cornea of a cadaver eye is removed by trephination. Cyanoacrylate glue is used to secure a large-diameter polymethylmethacrylate contact lens to the corneal rim.

Results: Excellent visualization for practice surgery is achieved with this technique. The adhesion of the contact lens to the cadaver eye maintains the anterior chamber sufficiently to perform phacoemulsification cataract extraction or pars plana vitrectomy.

Conclusions: This technique improves visualization of the intraocular structures during practice surgery, thereby enhancing the ability of the learning surgeon to perform and practice delicate surgical maneuvers. The procedure is simple, effective, and inexpensive.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archopht.121.1.16DOI Listing

Publication Analysis

Top Keywords

contact lens
16
practice surgery
16
visualization practice
12
lens artificial
8
artificial cornea
8
surgery cadaver
8
polymethylmethacrylate contact
8
cadaver eye
8
practice
5
contact
4

Similar Publications

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Perovskite-Based Smart Eyeglasses as Noncontact Human-Computer Interaction.

Adv Mater

January 2025

Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (ICCAS), Beijing Engineering Research Center of Nanomaterials for Green Printing Technology, Beijing National Laboratory for Molecular Sciences (BNLMS), Beijing, 100080, P. R. China.

More than 70% of human information comes from vision. The eye is one of the most attractive sensing sites to collect biological parameters. However, it is urgent to develop a cost-effective and easy-to-use approach to monitor eyeball information in a minimally invasive way instead of current smart contact lenses or camera-based eyeglasses.

View Article and Find Full Text PDF

Importance: For myopia control to be beneficial, it would be important that the benefit of treatment (slowed eye growth) is not lost because of faster than normal growth (rebound) after discontinuing treatment.

Objective: To determine whether there is a loss of treatment effect (rebound) after discontinuing soft multifocal contact lenses in children with myopia.

Design, Setting, And Participants: The Bifocal Lenses in Nearsighted Kids 2 (BLINK2) cohort study involved children with myopia (aged 11-17 years at BLINK2 baseline) who completed the BLINK Study randomized clinical trial.

View Article and Find Full Text PDF

Aim: To report the clinical and therapeutic particularities of pediatric keratoconus (KC).

Methods: Retrospective study focusing on patients aged less than 18 years, presenting with KC and followed in a tertiary reference center in Sfax, Tunisia.

Results: Our study involved 38 eyes of 20 children.

View Article and Find Full Text PDF