Background: Dental implants vary in design and surfaces. In addition, different surgical techniques have been used for implant insertion. The ITI Dental Implant System (Straumann AG, Waldenburg, Switzerland) has always required a one-stage technique, whereas the Brånemark System (Nobel Biocare AB, Gothenburg, Sweden) requires a two-stage technique.
Purpose: The aim of this study is to compare the outcome of fixed partial bridges in the maxilla supported by both ITI and Brånemark implants in a split-mouth design.
Materials And Methods: Twenty-eight patients with a residual anterior dentition in the maxilla were included in this split-mouth study. The Brånemark implants were used on one side and the ITI implants on the other side of the residual dentition according to a randomization procedure. A blocking size of four was used, giving equal probability of placing ITI or Brånemark implants in the right or left side of the jaw. The surgical and prosthetic procedures followed the guidelines given by the manufacturers. The prosthetic treatment with the two-implant systems was performed at the same time, and for that reason the healing period was 6 months for both systems. The observation period for all patients was 1 year after loading.
Results: Two Brånemark implants (in one patient) were lost before loading, and one ITI implant was lost 1 year after loading. There was no significant difference in survival rate. Radiographic examination of the bone level was performed at the time of delivery of the bridge and after 1 year. The mean marginal bone level at baseline was situated 1.9 mm from the reference point for the Brånemark implants and 1.5 mm for the ITI implants. With regard to the insertion depth used, these bone levels indicate that bone loss had taken place before baseline. However, between baseline and the 1-year examination, there was no significant change of the marginal bone (0.2 +/- 0.08 mm at the Brånemark implants and 0.1 +/- 0.11 mm at the ITI implants). The difference between results with the two implants was not statistically significant. Crater-form bone destructions were seen at some ITI implants, indicating periimplantitis. However, at only two implants were there clinical signs of periimplantitis.
Conclusions: No significant difference in survival rate or in marginal bone change could be demonstrated between the two systems. At some ITI implants (18%), crater-form bone loss was observed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1708-8208.2002.tb00161.x | DOI Listing |
PLoS One
January 2025
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Pharmacy Practice, Faculty of Pharmacy, Airlangga University, Surabaya, Indonesia.
Hydroxyapatite (HA) is widely used as a bone graft. However, information on the head-to-head osteoinductivity and in vivo performance of micro- and nanosized natural and synthetic HA is still lacking. Here, we fabricated nanosized bovine HA (nanoBHA) by using a wet ball milling method and compared its in vitro and in vivo performance with microsized BHA, nanosized synthetic HA (nanoHA), and microsized synthetic HA (HA).
View Article and Find Full Text PDFPLoS One
January 2025
Department of Orthopedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland.
Background: Low-profile double plating seems a viable alternative to conventional single plating for fixation of midshaft clavicle fractures. This study aims to compare the two techniques regarding healing, complications, and removal rate.
Methods: This retrospective cohort study included all patients >16 years that underwent plate fixation for midshaft clavicle fractures between 2020 and 2022 at one trauma-center.
J Bone Joint Surg Am
January 2025
Institute for Global Orthopaedics and Traumatology, University of California, San Francisco, San Francisco, California.
Background: Although delays in musculoskeletal care in low- and middle-income countries (LMICs) are well documented in the open fracture literature, the impact of surgical delays on closed fractures is not well understood. This study aimed to assess the impact of surgical delay on the risk of infection in closed long-bone fractures treated with intramedullary nailing in LMICs.
Methods: Using the SIGN (Surgical Implant Generation Network) Surgical Database, patients ≥16 years of age who were treated with intramedullary nailing for closed diaphyseal femoral and tibial fractures from January 2018 to December 2021 were identified.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!