Recent research shows that Monte Carlo diffusion methods are often the most efficient algorithms for solving certain elliptic boundary value problems. In this paper, we extend this research by providing two efficient algorithms based on the concept of "last-passage diffusion." These algorithms are qualitatively compared with each other (and with the best first-passage diffusion algorithm) in solving the classical problem of computing the charge distribution on a conducting disk held at unit voltage. All three algorithms show detailed agreement with the known analytic solution to this problem.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevE.66.056704 | DOI Listing |
Anal Chem
January 2025
Department of Earth and Environmental Sciences, University of Texas at Arlington, Arlington, Texas 76019, United States.
Fluorescence fluctuation spectroscopy experiments were conducted to better understand the complex mass transport dynamics of organic molecules in liquid-filled nanoporous media. Anodic aluminum oxide (AAO) membranes incorporating 10 and 20 nm diameter cylindrical pores were employed as model materials. Nile red (NR) dye was used as a fluorescent tracer.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Paediatric and Community Dentistry, Faculty of Dentistry, Minia University, Ard Shalaby, El Minia, 61519, Egypt.
Background: This study aimed to assess the histological and radiographic effects of sodium hexametaphosphate (SHMP) as a direct pulp capping (DPC) agent in immature permanent dog premolars.
Methods: A split-mouth design was employed with three healthy 4-month-old Mongrel dogs, each having 36 premolars. The premolars were randomly assigned to either SHMP or MTA.
Phys Med Biol
January 2025
Department of Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, GERMANY.
Orthotopic tumor models in pre-clinical translational research are becoming increasingly popular, raising the demands on accurate tumor localization prior to irradiation. This task remains challenging both in X-ray and proton computed tomography (xCT and pCT, respectively), due to the limited contrast of tumor tissue compared to the surrounding tissue. We investigate the feasibility of gadolinium oxide nanoparticles as multimodal contrast enhancement agent for both imaging modalities.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Medical Physics, Apollo Proton Cancer Centre, 100 Feet Road Taramani, Chennai, Tamil Nadu, India. Electronic address:
Objectives: The purpose of this study was to investigate the fundamental properties of spot-scanning proton beams and compare them to Monte Carlo (MC) simulations, both with and without CT calibration, using spatially diverse combinations of materials.
Methods: A heterogeneous phantom was created by spatially distributing titanium, wax, and thermocol to generate six scenarios of heterogeneous combinations. Proton pencil beams ranging in energy from 100 to 226.
J Neurosurg
January 2025
1Department of Neurosurgery, Baylor College of Medicine, Houston, Texas.
Objective: Deep brain stimulation (DBS) is an effective neurosurgical option for patients with treatment-resistant obsessive-compulsive disorder (OCD). Despite being more costly than neuroablative procedures of comparable efficacy, DBS has gained popularity over the years for its reversibility and adjustability. Although the cost-effectiveness of DBS has been investigated extensively in movement disorders, few economic analyses of DBS for psychiatric disorders exist.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!