Motion correction in MRI using an apparatus for dynamic angular position tracking (ADAPT).

Magn Reson Med

Center for Advanced Brain Imaging, Nathan S. Kline Institute, Orangeburg, New York, USA.

Published: January 2003

Motion during MRI examinations is a serious problem that degrades the quality of the data (images) acquired. Motion can be corrected during the postprocessing of the data; however, this approach is suboptimal and is typically limited to in-plane or translational motion. An apparatus for dynamic angular position tracking (ADAPT) for prospective angular motion correction has been developed. This application is capable of "tracking" the scanned region of interest by performing dynamic adjustments of orientation of the scanning plane. The operation of the apparatus is based on deuterium MR spectroscopy and does not rely on the use of magnetic field gradients. Orientation-sensitive deuterium quadrupolar interaction in a single crystal attached to a subject is used to monitor the angular position in magnetic fields. Measurements are performed with an independent spectrometer channel in the background of the MRI scans. This apparatus is very cost- and time-efficient because it utilizes the hardware already available on many spectrometers and can be used in parallel with MRI scans. Potentially, rotations by a fraction of one degree can be easily corrected and the angular position information can be rapidly updated.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.10329DOI Listing

Publication Analysis

Top Keywords

angular position
16
motion correction
8
apparatus dynamic
8
dynamic angular
8
position tracking
8
tracking adapt
8
mri scans
8
motion
5
angular
5
mri
4

Similar Publications

Insights into proprioceptive acuity assessed with a dynamic joint position reproduction task.

J Electromyogr Kinesiol

January 2025

Centro Polifunzionale di Scienze Motorie, Università degli Studi di Genova, Genoa, Italy; Department of Experimental Medicine, Section of Human Physiology, Università degli Studi di Genova, Genoa, Italy.

This study investigated proprioceptive acuity using the conventional joint position reproduction (JPR) task and a modified version, the Dynamic JPR task (D-JPR), during Concentric and Eccentric muscle contractions. Seventeen participants were recruited and received a tactile stimulus indicating the position cue at Initial (INI), Intermediate (INT), and Final (FIN) phases of movements, during either the concentric or eccentric phases. After the movement, they replicated the position where they received the stimulus.

View Article and Find Full Text PDF

Accurate head positioning is essential for diagnostics of benign paroxysmal positional vertigo (BPPV). This study aimed to quantify the head angles and angular velocities during traditional manual BPPV diagnostics in patients with positional vertigo. : A prospective, observational cohort study was conducted at a tertiary university hospital outpatient clinic.

View Article and Find Full Text PDF

MEMS Smart Glass with Larger Angular Tuning Range and 2D Actuation.

Micromachines (Basel)

December 2024

Institute of Nanostructure Technologies and Analytics (INA), Technological Electronics Department and Center for Interdisciplinary Nanostructure Science and Technology (CINSaT), University of Kassel, Heinrich-Plett-Straße 40, 34132 Kassel, Germany.

Millions of electrostatically actuatable micromirror arrays have been arranged in between windowpanes in inert gas environments, enabling active daylighting in buildings for illumination and climatization. MEMS smart windows can reduce energy consumption significantly. However, to allow personalized light steering for arbitrary user positions with high flexibility, two main limitations must be overcome: first, limited tuning angle spans by MEMS pull-in effects; and second, the lack of a second orthogonal tuning angle, which is highly required.

View Article and Find Full Text PDF

Objective: Dynamic navigation approaches are widely employed in the context of implant placement surgery. Implant surgery can be divided into immediate and delayed surgery according to the time of implantation. This retrospective study was developed to compare the accuracy of dynamic navigation system for immediate and delayed implantations.

View Article and Find Full Text PDF

Evaluating the performance of a new ergonomic laparoscopic needle holder for intracorporeal suturing.

PLoS One

January 2025

Instituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Ciudad de México, México.

In laparoscopy, the absence of ergonomics in the instruments affects the performance and efficiency of the surgeon, increasing the likelihood of developing musculoskeletal injuries. This article presents the development of a laparoscopic needle holder with an ergonomic handle and the experience in its use with surgeons in the intracorporeal suturing task. The handle of the laparoscopic needle holder consists of a semi-spherical piece that easily adapts to the palm of the surgeon's hand and improves the posture and ergonomics of the wrist, allowing the direct transmission of rotational movements around the longitudinal axis of the instrument towards the tip.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!