Aerosols concentration in the Candiota area applying different gravimetric methods of sampling and numeric modelling.

J Environ Monit

Fundaçdo Estadual de Proteção Ambiental, Rua Carlos Chagas 551707, Porto Alegre-RS 90030-020, Brazil.

Published: December 2002

The main purpose of the present work is to study the concentration of atmospheric particles in the Candiota region, in the state of Rio Grande do Sul, where the Presidente Médici coal power plant is located. Aerosol samples were collected at the studied locations between December 2000 and December 2001 during 24 h periods at 15 day intervals using HV PM10 and dichotomous samplers. Then, the values obtained with the ISCST (Industrial Source Complex Term) model, with the HV PM10 sampler at all studied stations, and with the dichotomous sampler at the 8 de Agosto station were compared with each other. The results show that the values for the model had been underestimated in relation to the HV PM10 data for the studied stations, but agreed with the values obtained with the dichotomous sampler.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b204816gDOI Listing