Objective: The aim of this study was to clarify whether Tc-99m HIG (Polyclonal Human Immunoglobulin G) can image and determine the severity of orbital involvement in patients with Graves' ophthalmopathy.

Materials And Methods: Twenty-six patients between 19 and 56 years old with Graves' ophthalmopathy were examined. All patients received approximately 370 MBq Tc-99m HIG by i.v. injection. Planar and SPECT examination were performed 4 hours after the injection. Visual and semiquantitative evaluations were performed for both orbits by two independent observers,

Results: Clinically active ophthalmopathy patients had noticeably increased orbital accumulation of Tc-99m HIG. In patients with inactive disease, and 14 of 19 had no uptake, whereas 5 patients had orbital radioactivity accumulation. The duration of Graves' ophthalmopathy did not correlate with the presence of active ophthalmopathy and Tc-99m HIG grade. There was no correlation between clinical classification and clinical activity (r = 278). There was a good correlation between clinical activity and the radioactivity grade with r = 0.666 (p = 0.01). The clinical classification closely correlated with Tc-99m HIG grade (r = 0.423, p = 0.05).

Conclusion: Tc-99m HIG scan can clearly identified clinically active patients, and subclinicial inflammation can be shown by this scintigraphic evaluation. The current preliminary results suggested that Tc-99m HIG SPECT might be useful for the assessment of disease activity in Graves' ophthalmopathy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02988642DOI Listing

Publication Analysis

Top Keywords

tc-99m hig
28
graves' ophthalmopathy
16
polyclonal human
8
human immunoglobulin
8
clinically active
8
active ophthalmopathy
8
hig grade
8
correlation clinical
8
clinical classification
8
clinical activity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!