A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An automated method to position prosthetic components within multiple anatomical spaces. | LitMetric

An automated method to position prosthetic components within multiple anatomical spaces.

Comput Methods Programs Biomed

Laboratorio di Tecnologia Medica, Istituti Ortopedici Rizzoli, Via di Barbiano, 1/10, 40136, Bologna, Italy.

Published: February 2003

The level of fit and fill of a stem in the host femur is the most critical factor for the mechanical stability and success of the prosthesis. It would be useful to have a simulation tool able to investigate the anatomical compatibility of a new implant in a large library of femoral anatomies in the early phases of the design process. In order to realise this tool, it is necessary to develop an automatic method for the positioning of the stem in a database of anatomies. The aim of this study was to develop and evaluate a method for the automatic positioning of the stem geometry in the anatomical CT dataset. Two different strategies were considered: a completely automatic registration technique and a semi-automatic method based on an anatomical referencing. The two procedures were compared to the manual positioning obtained by an expert surgeon in a set of nine CT datasets. For both methods in each femur the positioning and the orientation of the stem were good. The results showed a better level of fitting for the automatic method, while the shift of the hip joint centre was lower for the anatomical referencing technique. However, the anatomical referencing method requires a higher computational effort without being significantly better than the automatic method. For this reason, the automatic method should be chosen to develop the automatic positioning of a stem in a database of anatomies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0169-2607(02)00010-xDOI Listing

Publication Analysis

Top Keywords

automatic method
16
positioning stem
12
anatomical referencing
12
develop automatic
8
stem database
8
database anatomies
8
automatic positioning
8
automatic
7
method
7
anatomical
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!