A previously developed test rig was used as starting point for designing a portable slip meter with two new features. First, an inflatable pneumatic test wheel, consisting of six slider units, was introduced as the impacting contact element relative to floor surface. Second, an inductive trigger was built into the system to facilitate a precise timing of the slider-floor contact during the test. This new test rig was designed to measure transitional friction properties of contaminated floor surfaces during simulated heel strike, which is considered the most critical phase of gait from the slip and fall point of view. Another objective was to quantify the validity and reliability of this test method in the laboratory, but not yet in the field. The measurement process was evaluated on eight wet and oily floor surfaces (vinyl and ceramic tile floorings) using two slider materials (plain, profiled), two normal loads (100, 200 N), and two sliding velocities (0.15, 0.30 m/s) as independent variables. The outputs of the portable slip meter, in terms of transitional friction coefficients, were compared to force platform-based friction values and to slip resistance values obtained with a slip simulator apparatus for laboratory testing of shoes and floor surfaces. The outputs were also evaluated against slipperiness ratings made by three male subjects in paired comparison trials, in which the subjects walked over eight wet floor surfaces wearing shoes with the plain soling material. The results showed that test option 200 N and 0.15m/s led to optimum validity despite its tendency to promote frictional vibrations (stick-slip) in the contact surface. Compared to the lower sliding speed, the higher speed reduced both stick-slip and measurement bias. Test option 200 N and 0.30 m/s was the most reliable one in this experiment. It yielded lower friction coefficients than any other test option and reduced the likelihood of underestimating slip and fall hazards. The results implied that the minimum friction coefficient was 0.25 for preventing a fall on wet floor surfaces, whereas the limit for preventing a slip was in the range 0.30-0.35. Transitional friction measurement was found to be a valid and reliable indicator for slip resistance. A more accurate control of the normal force during testing is needed for actual field use of the test method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0001-4575(01)00105-1DOI Listing

Publication Analysis

Top Keywords

floor surfaces
20
portable slip
12
slip meter
12
transitional friction
12
test option
12
slip
9
test
9
validity reliability
8
simulated heel
8
heel strike
8

Similar Publications

Urban overheating significantly affects thermal comfort and livability, making it essential to understand the relationship between urban form and land surface temperature (LST). While the horizontal dimensions of urban form have been widely studied, the vertical structures and their impact on LST remain underexplored. This study investigates the influence of three-dimensional urban form characteristics on LST, using ECOSTRESS sensor data and four machine learning models.

View Article and Find Full Text PDF

Proximity of maxillary molar palatal roots to adjacent structures for endodontic microsurgery: a cone-beam computed tomography study.

BMC Oral Health

January 2025

Beijing Yakebot Technology Co., Ltd, F-616-West Building, Yonghe Plaza, No. 28 Andingmen Dongdajie, DongCheng District, Beijing, 100007, China.

Background: The surgical complexity associated with the palatal roots of maxillary molars was considerably elevated. Previous studies on the relationships between maxillary molar roots and the maxillary sinus or cortical plates have focused on individual root observation without considering the positional relationship between buccal and palatal roots or analysing the surgical pathway of maxillary molar palatal roots. This study aimed to investigate the relationship between maxillary molar palatal roots and adjacent anatomical structures to provide a reference for performing palatal roots endodontic microsurgery.

View Article and Find Full Text PDF

The laryngeal mound (LM) formed the caudal part of the pharyngeal floor, which varied in position, shape, and length at different ages. This work aimed to study the morphogenesis of the LM in the embryonic and post hatching periods grossly, histologically, and by scanning electron microscopy using forty-eight Japanese quails. The LM primordia appeared on the 8th day of incubation as a raised elevation carried on a deep median symmetrical sulcus (glottis primordium).

View Article and Find Full Text PDF

First Report of Causing Root Rot of Incense Cedar in Tennessee and the United States.

Plant Dis

January 2025

Tennessee State University, Otis Floyd Nursery Research Center, 472 Cadillac Lane, McMinnville, Tennessee, United States, 37110;

Incense cedar [ (Torr.) Florin] is a coniferous evergreen tree, indigenous to western North America, that is being evaluated in Tennessee for its adaptability to eastern U.S.

View Article and Find Full Text PDF

Study on numerical simulation of groundwater flow field and slope stability in multi-aquifer open pit mine.

Sci Rep

December 2024

Liaoning Institute of Technology and Equipment for Mineral Resources Development and Utilisation in Higher Educational Institutions, Liaoning Technical University, Fuxin, 123000, Liaoning, China.

Water is one of the most important influences on slope stability in open pit mines. In order to solve the problem of slope stability analysis in multi-aquifer open pit mines, the open pit mine in Block I of Thar Coalfield in Pakistan with multiple aquifers was taken as the research background. The groundwater flow field at different excavation phases was analyzed by numerical simulation method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!