A comparison of screening methods in school-aged children.

Otolaryngol Head Neck Surg

Otology Group-San Antonio, 9150 Huebner Road, Suite 160, San Antonio, TX 78240, USA.

Published: December 2002

Objective: We sought to compare the findings of 3 different hearing screening methods in school-aged children.

Study Design And Setting: Prospective testing of second- and third-grade students in their schools was carried out.

Methods: Three hundred children (599 ears) were screened by using 3 test modalities, pure-tone audiometry, distortion product otoacoustic emissions (DPOAE), and tympanometry.

Results: All of the tests were normal in 532 ears (89%), and all were abnormal in 12 ears (2%). Tympanometry yielded the most abnormalities (8.3%), and pure-tone testing demonstrated the fewest (3.3%), with a positive rate of 6.3% for DPOAE testing. False-positive rates were 1.2%, 4.2%, and 6.4% for pure tones, DPOAE, and tympanometry, respectively, when normal results on pure-tones or DPOAE were taken to represent true hearing.

Conclusion/significance: We continue to recommend pure-tone testing as an effective screening method, with follow-up by using otoacoustic emissions in those who fail the pure-tone test.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mhn.2002.129734DOI Listing

Publication Analysis

Top Keywords

screening methods
8
methods school-aged
8
otoacoustic emissions
8
pure-tone testing
8
comparison screening
4
school-aged children
4
children objective
4
objective sought
4
sought compare
4
compare findings
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!