A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Proton spin-lock ratio imaging for quantitation of glycosaminoglycans in articular cartilage. | LitMetric

Proton spin-lock ratio imaging for quantitation of glycosaminoglycans in articular cartilage.

J Magn Reson Imaging

MMRRCC, Department of Radiology, Stellar-Chance Laboratories, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania 19104-6100, USA.

Published: January 2003

Purpose: To quantify glycosaminoglycans (GAG) in intact bovine patellar cartilage using the proton spin-lock ratio imaging method. This approach exploits spin-lattice relaxation time in the rotating frame (T(1rho)) imaging and T(1rho) relaxivity (R(1rho)).

Materials And Methods: All the magnetic resonance imaging (MRI) experiments were performed on a 4-T whole-body GE Signa scanner (GEMS, Milwaukee, WI), and spectroscopy experiments of chondroitin sulfate (CS) phantoms were done on a 2-T custom-built spectrometer. A custom-built 11-cm-diameter transmit-receive birdcage coil, which was tuned to a proton frequency of 170 MHz, was employed for the imaging experiments. T(1rho) measurements were made using a fast spin echo (FSE) sequence pre-encoded with a three-pulse cluster consisting of two 90 degrees hard pulses separated by a low-power rectangle pulse for spin-locking.

Results: The methodology is first validated on CS phantoms and then used to quantify GAG content in intact bovine cartilage (N = 5). There is a good agreement between the GAG map calculated from the T(1rho) ratio imaging method (71 +/- 4%) and GAG measured from spectrophotometric assay (75 +/- 5%) in intact bovine tissue.

Conclusion: We have demonstrated a proton spin-lock ratio imaging method to quantify absolute GAG distribution in the cartilage in a noninvasive and nondestructive manner.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.10228DOI Listing

Publication Analysis

Top Keywords

ratio imaging
16
proton spin-lock
12
spin-lock ratio
12
intact bovine
12
imaging method
12
imaging
7
gag
5
proton
4
ratio
4
imaging quantitation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!