We report here an efficient photocatalytic amperometric sensor for the determination of dissolved oxygen (DO) in phosphate buffer solution using a disposable copper-plated screen-printed carbon electrode (CuSPE). The photoelectrochemical activity toward DO of the CuSPE was related to the formation of a p-type semiconductor Cu(I)2O. The solution pH and biased potential (E(bias)) were systematically optimized as pH 8 PBS and -0.7 V vs Ag/AgCl, respectively. Under optimized conditions, the calibration plot was linear in the range of 1-8 ppm with sensitivity and regression coefficient of 23.51 (microA cm2)(-1) ppm(-1) and 0.9982, respectively. The reproducibility of the system was good with seven successive measurements of DO yielding a RSD value of 1.87%. Real sample assays for groundwater and tap water were also consistent with those measured by a commercial DO meter. The principle used in DO measurement has an opportunity to extend into various research fields.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac020058rDOI Listing

Publication Analysis

Top Keywords

copper-plated screen-printed
8
screen-printed carbon
8
photoelectrochemical oxygen
4
oxygen sensor
4
sensor copper-plated
4
carbon electrodes
4
electrodes report
4
report efficient
4
efficient photocatalytic
4
photocatalytic amperometric
4

Similar Publications

Hydrophobic AlO Surfaces by Adsorption of a SAM on Large Areas for Application in Solar Cell Metallization Patterning.

ACS Appl Mater Interfaces

February 2021

Institute of Inorganic and Analytical Chemistry, University of Freiburg, Albertstraße 21, 79104 Freiburg, Germany.

A resist-free metallization of copper-plated contacts is attractive to replace screen-printed silver contacts and is demonstrated on large-area silicon heterojunction (SHJ) solar cells. In our approach, a self-passivated Al layer is used as a mask during the plating process. In this study, Al/AlO or AlO plating masks are further functionalized by a self-assembled monolayer (SAM) of octadecyl phosphonic acid (ODPA).

View Article and Find Full Text PDF

A novel and sensitive detection method based on photoelectrocatalytic oxidation of o-diphenols was demonstrated on a copper-plated screen-printed carbon electrode (designated CuSPE) in pH 8 phosphate buffer solution. The o-diphenols can be detected amperometrically through electrochemical oxidation at a low applied potential of -0.1 V versus Ag/AgCl, where the CuSPE is much less subject to interfering reactions.

View Article and Find Full Text PDF

We report here an efficient photocatalytic amperometric sensor for the determination of dissolved oxygen (DO) in phosphate buffer solution using a disposable copper-plated screen-printed carbon electrode (CuSPE). The photoelectrochemical activity toward DO of the CuSPE was related to the formation of a p-type semiconductor Cu(I)2O. The solution pH and biased potential (E(bias)) were systematically optimized as pH 8 PBS and -0.

View Article and Find Full Text PDF

Selective detection of o-diphenols (e.g., catechol, dopamine, and pyrogallol) in the presence of simple phenols, m- and p- derivative diphenols, and ascorbic acid has been demonstrated on copper-plated screen-printed electrodes (CuSPEs) in pH 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!