Chronically implanted ventricular pacing and defibrillator (ICD) leads can adhere to the tricuspid valve. This study examined the effect of lead extraction, and laser sheath extraction in particular, on tricuspid valve regurgitation. Lead extraction was first tried with traction using limited force followed by a laser sheath if not successful. Tricuspid valve regurgitation before and after extraction was evaluated with transesophageal echocardiography and graded from 0 (none) to 4 (severe). A change in regurgitation was considered clinically relevant if it increased with two grades or more and resulted in at least grade 3 regurgitation. Fifty ventricular leads were extracted in 43 consecutive patients, including 14 ICD leads. In 20 patients (group I) leads were removed without a (laser) sheath crossing the tricuspid valve, in 23 patients (group II) leads were extracted with lasing across the valve. The mean time from implant was 43 +/- 43 months and 99 +/- 78 months, respectively, (P = 0.007). Tricuspid regurgitation increased in five (12%) patients. In group I only in one patient the laser failed proximal of the valve and forceful traction was subsequently used, and in group II this occurred in four (17%) patients. This difference did not reach statistical significance even excluding the patient from group I (P = 0.111). The increase of tricuspid regurgitation cautions against indiscriminate extraction of superfluous leads. There is a trend that when tools like a laser sheath are necessary the chance of tricuspid valve damage increases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1046/j.1460-9592.2002.01583.x | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Second Division of Cardiology, Cardiac-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy.
This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.
View Article and Find Full Text PDFFront Pediatr
January 2025
Heart Center, Women and Children's Hospital, Qingdao University, Qingdao, China.
Background: This study aimed to assess right ventricular (RV) endocardial fibroelastosis (EFE) in fetuses with critical pulmonary stenosis (CPS) and pulmonary atresia with intact ventricular septum (PA-IVS) and to investigate the implications of RV EFE for circulatory outcomes.
Methods: Fetal echocardiographic data from July 2018 to January 2021 were collected. Three reviewers independently graded EFE based on the presence and extent of endocardial echogenicity.
Rev Cardiovasc Med
January 2025
Cardiovascular Department IRCCS (Istituto di Ricerca e Cura a Carattere Scientifico) Humanitas Research Hospital, 20089 Rozzano, Milan, Italy.
Tricuspid regurgitation (TR) is a potentially lethal condition and represents a significant clinical challenge both for clinical and interventional cardiologists. Traditionally managed medically and surgically, transcatheter therapies are now an emerging option, especially in patients with prohibitive surgical risk due to age or comorbidities. Transcatheter tricuspid valve replacement (TTVR) is emerging as a potential solution for patients suffering from TR with positive clinical data supporting its use in a wide range of anatomies and clinical settings.
View Article and Find Full Text PDFRev Cardiovasc Med
January 2025
Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital Ganzhou Hospital, Guangdong Academy of Medical Sciences, 341000 Ganzhou, Jiangxi, China.
Background: Prognosis assessments for transcatheter aortic valve implantation (TAVI) patients remain challenging, particularly as the indications for TAVI expand to lower-risk patients. This study assessed the prognostic value of the tricuspid regurgitation impact on outcomes (TRIO) score in patients after TAVI.
Methods: This single-center study included 530 consecutive patients who underwent TAVI.
Cureus
December 2024
Internal Medicine, Cooper University Hospital, Camden, USA.
This case report presents a complex and challenging scenario of recurrent () bacteremia and tricuspid valve endocarditis in a 77-year-old male patient with multiple comorbidities and indwelling medical devices. The patient's medical history was significant for T4 paraplegia, neurogenic bladder requiring a chronic indwelling suprapubic catheter, heart block status post-permanent pacemaker placement, type 2 diabetes mellitus, chronic kidney disease, and chronic sacral wounds. The case highlights the difficulties in managing antibiotic-resistant infections, particularly in patients with implantable devices and chronic wounds.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!