Breakthrough of polymers in interactive liquid chromatography.

J Chromatogr A

Polymer-Analysis Group, Department of Chemical Engineering, University of Amsterdam, Nieuwe Achtergracht 166, 1018 WV Amsterdam, The Netherlands.

Published: December 2002

Two separate peaks are observed for narrow polymer standards in both isocratic and gradient HPLC. One peak appears around the solvent front (the "solvent-plug peak" or "breakthrough peak"), whereas the second peak is retained significantly--or even highly. Although the effect has been observed many times before, it has never been rigorously explained. In this paper we provide a detailed explanation for the breakthrough peak. The two completely separate peaks are demonstrated not to represent to different fractions of the sample (e.g., the low- and high-molecular-mass parts of the distribution). Both peaks are representative of the entire polymeric sample for narrow polymer standard. Because the amount of the polymer in the breakthrough peak may vary, the quantitative analysis of the polymers by LC is jeopardized. The effects of the sample solvent, the (initial) mobile phase composition, the injection volume, the injected sample concentration, the column temperature, and the analyte structure and molecular mass on the breakthrough peak were investigated in LC experiments involving standards of polystyrene and poly(methyl methacrylate). Three necessary and sufficient conditionsare suggested for the breakthrough phenomenon to be observed. Recommendations to avoid the breakthrough phenomenon are given, culminating in a structured method for selecting the best possible sample solvents.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0021-9673(02)01483-8DOI Listing

Publication Analysis

Top Keywords

breakthrough peak
12
separate peaks
8
narrow polymer
8
breakthrough phenomenon
8
breakthrough
6
peak
5
sample
5
breakthrough polymers
4
polymers interactive
4
interactive liquid
4

Similar Publications

Wavefront sensing: A breakthrough for objective evaluation of dynamic accommodation in accommodative dysfunctions.

Comput Biol Med

January 2025

Centre of Physics of the Universities of Minho and Porto, University of Minho, 4710-057, Braga, Portugal. Electronic address:

The purpose of this study was to use wavefront sensing as an objective method to detect and assess dynamic accommodation in subjects with accommodative dysfunctions and symptoms related to near-vision tasks. Sixty-three subjects were divided into control (N = 18), symptomatic without any accommodative dysfunction (SWD) (N = 18), infacility of accommodation (INFA) (N = 6), excess of accommodation (EA) (N = 9), and insufficiency of accommodation (INSA) (N = 12) groups. Accommodation was stimulated in different cycles of accommodation and disaccommodation while ocular aberrations were measured.

View Article and Find Full Text PDF

Objective: Our study aimed to investigate antibody responses in omicron BF.7-infected patients after being vaccinated with inactivated SARS-CoV-2.

Methods: Blood serum samples were collected every 2-7 d, 1 w before infection, during the acute infection period and recovery period, and every month after recovery to detect IgG, IgM, IgA, neutralizing antibodies, and neutralizing antibodies against different omicrons in the acute phase.

View Article and Find Full Text PDF

Impact of SARS-CoV-2 inactivated vaccine on symptoms following omicron variant breakthrough infection.

Vaccine

January 2025

Department of Microbiology and Infectious Disease Center, School of Basic Medical Sciences, Peking University, Beijing 100191, China.. Electronic address:

The SARS-CoV-2 Omicron variant and its sublineages continue to circulate widely. Clinical outcomes with this variant differ among individuals, primarily influenced by host immunity. Previous studies have explored the relationship between immune responses and severe diseases in infected or convalescent patients.

View Article and Find Full Text PDF

Anti-ambipolar transistors (AAT) are considered as a breakthrough technology in the field of electronics and optoelectronics, which is not only widely used in diverse logic circuits, but also crucial for the realization of high-performance photodetectors. The anti-ambipolar characteristics arising from the gate-tunable energy band structure can produce high-performance photodetection at different gate voltages. As a result, this places higher demands on the parametric driving range (ΔVg) and peak-to-valley ratio (PVR) of the AAT.

View Article and Find Full Text PDF

Hemophilia A (HA) patients under emicizumab prophylaxis may require the concomitant use of procoagulant factors for breakthrough bleedings or immune tolerance induction (ITI). The aim of this study is to evaluate the ex vivo procoagulant effect of plasma-derived FVIII concentrates containing von Willebrand factor (pdFVIII/VWF) in samples from patients with severe HA without inhibitors on emicizumab prophylaxis. Samples from healthy controls (HC) and HA patients were drawn in sodium citrate plus corn trypsin inhibitor tubes and spiked with increasing concentrations of pdFVIII/VWF concentrates (10-400 IU/dL) (Fanhdi/Alphanate, Grifols), activated prothrombin complex concentrate (aPCC, 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!