Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A method based on the coupling of capillary electrophoresis with mass spectrometry (CE/MS) was developed for the monitoring of 3-quinuclidinol and its four N-alkyl derivatives (methyl, ethyl, propyl and isopropyl derivatives). A fragmentation study (collision-induced dissociation of ions in an ion trap) and optimization of the ion optics set-up for CE/MS experiments using direct infusion of a methanolic solution of the standards into the mass spectrometer were carried out in advance. Molecular ions of all quaternary compounds and the quasi-molecular ion [M + H]+ of free 3-quinuclidinol prevail in the mass spectra. In the MS/MS of propyl and isopropyl derivatives, the elimination of the alkyl chain dominates, leading to the ion at m/z 128. The fragmentation of the other compounds is more complex. Previous CE separation of the mixture of isobaric propyl and isopropyl derivatives is necessary for their unambiguous identification. A 10 mM ammonium acetate buffer (pH 4.0) is the optimum running electrolyte, allowing the CE separation of methyl, ethyl, propyl and isopropyl derivatives. A 0.5% (v/v) solution of acetic acid in methanol provides sufficient detection sensitivity when used as the sheath liquid. Limits of detection of 0.1 ppm for 3-quinuclidinol and 0.05 ppm for quaternary derivatives were achieved under the optimum conditions. The optimized method was applied to the determination of 3-quinuclidinol and related quaternary derivatives spiked into a sample of pond water. The experimental set-up for CE/MS/MS was investigated, which strongly increases the identification capability of the technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jms.380 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!