Background: Coronary flow velocity reserve (CFVR), defined as the ratio of maximal hyperaemic to baseline flow velocity, has been validated as a marker of physiological significance of a coronary lesion. Clinically, this parameter is measured invasively during X-ray angiography using the Doppler guide wire. With magnetic resonance (MR) imaging it is possible to quantify CFVR non-invasively.
Design: The purpose of the study was to compare CFVR, acquired with MR imaging and the Doppler guide wire in patients with coronary artery disease.
Methods: Twenty-two patients suffering from one- or two-vessel coronary artery disease as derived from diagnostic X-ray coronary angiography were included. Coronary flow velocity reserve was measured at baseline and during maximal hyperaemia, obtained by intravenous administration of adenosine using MR phase contrast velocity quantification. Within 2 weeks CFVR was measured invasively with a Doppler guide wire.
Results: In 26 coronary arteries CFVR was acquired with both techniques. Mean CFVR in the stenosed and healthy reference arteries was 1.5 +/- 0.7 and 2.7 +/- 1.0 (P < 0.01) respectively for MR measurements and 1.9 +/- 0.7 and 3.1 +/- 0.6 (P < 0.01) respectively for Doppler measurements. Bland-Altman analysis revealed a non-significant mean difference between the two techniques of 0.4 +/- 1.2.
Conclusion: In a selected group of stable patients with coronary artery disease MR flow velocity quantification provides non-invasive data equivalent to the invasive Doppler guide wire data. Variability in both the MR and Doppler ultrasound measurement resulted in a significant scatter of data without systematic difference.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00019501-200211000-00003 | DOI Listing |
J Feline Med Surg
January 2025
Department of Clinical Science, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Objectives: Cardiovascular complications are well known in humans with autosomal dominant polycystic kidney disease (PKD), but limited data exist for cats. This study aimed to assess echocardiographic changes, cardiac troponin I (cTnI) levels and systolic blood pressure (SBP) in Persian cats with PKD to detect early cardiac abnormalities.
Methods: In total, 52 Persian and mixed-Persian cats were enrolled, with 26 cats in the control group and 26 diagnosed with PKD via ultrasound due to the unavailability of genetic testing.
Alzheimers Dement
December 2024
University of Southern California, Los Angeles, CA, USA.
Background: Cerebrovascular reactivity (CVR) is a marker of cerebrovascular function defined by blood flow changes in response to vasoactive stimuli, which may represent a valuable indicator of risk for vascular brain injury and cognitive decline. Understanding of sex specific CVR patterns is limited, yet likely important for understanding vascular risk. Previous research on sex differences in CVR is mixed, and has predominantly focused on younger adults and utilized Transcranial Doppler ultrasound approaches that focus on large intracranial artery flow.
View Article and Find Full Text PDFEchocardiography
January 2025
Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Cardiovascular (CV) diseases caused 20.5 million deaths in 2021, making up nearly one-third of global mortality. This highlights the need for practical prognostic markers to better classify patients and guide treatment, especially in ischemic heart disease (IHD), which represents one of the leading causes of CV mortality.
View Article and Find Full Text PDFMagn Reson Med
December 2024
Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA.
Purpose: Proton magnetic resonance spectroscopic imaging ( -MRSI) provides noninvasive spectral-spatial mapping of metabolism. However, long-standing problems in whole-brain -MRSI are spectral overlap of metabolite peaks with large lipid signal from scalp, and overwhelming water signal that distorts spectra. Fast and effective methods are needed for high-resolution -MRSI to accurately remove lipid and water signals while preserving the metabolite signal.
View Article and Find Full Text PDFWorld J Gastrointest Endosc
December 2024
Department of Emergency Medicine, General Hospital of Larissa, Larisa 41221, Greece.
The Baveno VII consensus, released in 2023, recommends that the endoscopic treatment of choice for managing bleeding gastric varices (GV) is endoscopic ultrasound (EUS)-guided treatment, specifically EUS-guided cyanoacrylate (CYA) glue injection. This approach has been endorsed due to its efficacy in controlling bleeding while reducing rebleeding rates, compared to other endoscopic techniques. Despite its efficacy, CYA injection for GV has been linked to rare but serious adverse events, such as glue embolization leading to pulmonary embolism, infection/bacteremia, splenic infarction, intra-procedural and post-procedural complications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!