Fusion of morphology and function has been shown to improve diagnostic accuracy in many clinical circumstances. Taking this into account, a number of instruments combining computed tomography (CT) with positron emission tomography (PET) or single-photon emission tomography (SPET) are appearing on the market. The aim of this study was to evaluate a simple and cost-effective approach to generate fusion images of similar quality. For the evaluation of the proposed approach, patients with neuroendocrine abdominal tumours with liver metastases were chosen, since the exact superimposition in the abdomen is more difficult than in other regions. Five hours following the injection of 110 MBq (111)In-DTPA-octreotide, patients were fixed in a vacuum cushion (MED-TEC, Vac-Loc) and investigated with helical CT in a mid-inspiration position ( n=14). Directly following the CT, a SPET study (SPET1) of the abdominal region was performed without changing the position of the patient. A second SPET study (SPET2), 24 h p.i., was acquired after repositioning the patient in his or her individually moulded vacuum cushion. A total of nine markers suitable for imaging with CT and SPET were fixed on the cushion. Datasets were fused by means of internal landmarks (e.g. metastases or margin of abdominal organs) or by the external markers. Image fusion using external markers was fast and easy to handle compared with the use of internal landmarks. Using this technique, all lesions detectable by SPET ( n=28) appeared exactly superpositioned on the respective CT morphology by visual inspection. Image fusion of CT/SPET1 and CT/SPET2 showed a mean deviation of the external markers that in the former case was smaller than the voxel size of 4.67 mm: 4.17+/-0.61 (CT/SPET1; +/-SD) and 5.52+/-1.56 mm (CT/SPET2), respectively. Using internal landmarks, the mean deviation of the chosen landmarks was 6.47+/-1.37 and 7.78+/-1.21 mm. Vector subtraction of corresponding anatomical points of the CT and the re-sampled SPET volume datasets resulted in a similar accuracy. Vector subtraction of the metastases showed a significantly less accurate superimposition when internal landmarks were used ( P<0.001). The vacuum cushion did not affect the image quality of CT and SPET. The proposed technique is a simple and cost-effective way to generate abdominal datasets suitable for image fusion. External markers positioned on the cushion allow for a rapid and robust overlay even if no readily identifiable internal landmarks are present. This technique is, in principle, also suitable for CT/PET fusion as well as for fusions of MRI data with PET or SPET.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-002-1013-0DOI Listing

Publication Analysis

Top Keywords

internal landmarks
16
external markers
12
simple cost-effective
8
emission tomography
8
vacuum cushion
8
spet study
8
image fusion
8
vector subtraction
8
spet
6
landmarks
5

Similar Publications

Unlabelled: Accurate assessment of shoulder range of motion (ROM) is crucial for evaluating patient progress. Traditional manual goniometry often lacks precision and is subject to inter-observer variability, especially in measuring shoulder internal rotation (IR). This study introduces an artificial intelligence (AI)-based approach that uses clinical photography to improve the accuracy of ROM quantification.

View Article and Find Full Text PDF

The anterolateral ligament (ALL) is considered a secondary stabilizer of internal rotation and, due to proximity to the lateral collateral ligament (LCL), it may contribute to anterolateral rotatory stability. This study characterized the anatomy of the ALL and associated tissues of the anterolateral complex (ALC) to determine if structural and histological compensatory adaptations exist in patients without an ALL. Forty-nine cadaveric knees were dissected from distal-to-proximal using established landmarks with the aid of internal rotation stress to localize the ALL (if present), LCL, iliotibial band (ITB), and anterolateral capsule.

View Article and Find Full Text PDF

Gastric cancer (GC) is a major cause of global cancer mortality with high levels of heterogeneity. To explore geospatial interactions in tumor ecosystems, we integrated 2,138 spatial transcriptomic regions-of-interest (ROIs) with 152,423 single-cell expression profiles across 226 GC samples from 121 patients. We observed pervasive expression-based intratumor heterogeneity, recapitulating tumor progression through spatially localized and functionally ordered subgroups associated with specific immune microenvironments, checkpoint profiles, and genetic drivers such as SOX9.

View Article and Find Full Text PDF

Seepage accelerates the weathering and destruction of cultural heritage sites, posing a major preservation challenge, while the concealed nature of seepage channels complicates their detection due to noninvasive requirements. In this study, we applied a comprehensive geophysical approach, integrating electrical resistivity tomography (ERT) and self-potential (SP) techniques, to image seepage channels within the Leitai heritage site. These potential seepage channels have already caused a collapse pit measuring 3.

View Article and Find Full Text PDF

Statins (3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitors) play a vital role in managing and preventing cardiovascular disease, particularly in elderly populations who face elevated risks for atherosclerosis and related conditions. This review delves into the mechanisms of statin action, emphasizing their impact on low-density lipoprotein cholesterol levels, anti-inflammatory properties, and potential genetic factors influencing efficacy and drug tolerability. Consideration is given to statin intolerance and management strategies, drug interactions, and guidelines for primary and secondary prevention of cardiovascular events.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!