Purpose: A unique method of delivering radiation dose to the coronary vessel wall to prevent restenosis is by direct injection of radioactive compounds into the vessel wall using a specially designed angioplasty balloon catheter. The radiation dose distribution resulting from such intramural delivery was investigated using Monte Carlo simulations.

Materials And Methods: The radioisotope source distribution was modeled for two configurations within the vessel wall: (1) uniform to a depth of 0.5 mm and (2) confined to discrete pools surrounding the delivery injection ports. Monte Carlo MCNP4B computer simulations were utilized to estimate the associated radiation dose distribution for the following radioisotopes: 188Re, 186Re, 32P, 153Sm, 111In, 123I, and 99mTc.

Results: For the uniform case where the radioisotopes are distributed uniformly to the depth of 0.5 mm into the vessel wall, an essentially constant radiation dose is delivered within the source distribution. Outside of the source volume, the dose falls off at a rate depending on the emission properties of the particular radioisotope. The nonuniform case involving discrete pools of activity showed the dose distribution being confined largely to the regions surrounding the delivery ports with significant regions between these ports receiving very little dose.

Conclusions: Direct injection of selected radioisotopes into the arterial wall appears to represent a potentially effective method for delivering radiation dose for the prevention of restenosis. Sufficiently high doses may be obtained from relatively low activity and the dose falls off rapidly outside of the target area for certain radioisotopes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1522-1865(02)00142-7DOI Listing

Publication Analysis

Top Keywords

radiation dose
20
dose distribution
16
vessel wall
16
monte carlo
12
direct injection
12
dose
9
distribution intramural
8
intramural delivery
8
balloon catheter
8
method delivering
8

Similar Publications

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

This study presents a patient with a PET-CT detected residual lacrimal sac tumor who was treated with intensity modulated proton therapy (IMPT) and concurrent chemotherapy. The patient a 49-year-old male diagnosed with squamous cell carcinoma of the left lacrimal sac had under-went endoscopic surgery. Postoperative PET-CT implied tumor residual in the left lacrimal sac.

View Article and Find Full Text PDF

Inverse dose protraction effects of high-LET radiation: evidence and significance.

Mutat Res Rev Mutat Res

January 2025

Radiation Epidemiology Branch, National Cancer Institute, MD 20892-9778, USA; Faculty of Health, Science and Technology, Oxford Brookes University, Headington Campus, OX3 0BP, UK.

Biological effects of ionizing radiation vary with radiation quality, which is often expressed as the amount of energy deposited per unit length, i.e., linear energy transfer (LET).

View Article and Find Full Text PDF

Radiography is a field of medicine inherently intertwined with technology. The dependency on technology is very high for obtaining images in ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI). Although the reduction in radiation dose is not applicable in US and MRI, advancements in technology have made it possible in CT, with ongoing studies aimed at further optimization.

View Article and Find Full Text PDF

Background And Purpose: Radiation-induced lymphopenia (RIL) may be associated with a worse prognosis in pancreatic cancer. This study aimed to develop a normal tissue complication probability (NTCP) model to predict severe RIL in patients with pancreatic cancer undergoing concurrent chemoradiotherapy (CCRT).

Materials And Methods: We reviewed pancreatic cancer patients treated at our facility for model training and internal validation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!