It is often helpful to assess the pressures exerted upon the bony prominences when monitoring the likely outcome of pressure ulcer prevention or treatment. However, in the clinical setting, hard pressure sensors may damage the skin and operational difficulties may influence their reliability and validity. The authors have developed a multi-pad pressure sensor and tested its clinical reliability and validity. The inter-rater and intra-rater reliability were calculated using the coefficient of variation data from 10 patients. After a comparison analysis, the multi-pad was more reliable than a single-pad type pressure sensor. A validation test was conducted in 79 elderly patients. The mean interface pressures recorded among patients who had erythema or stage I pressure ulcers at the sacrum were significantly higher than were the contact pressures measured in patients with no pressure damage. The pressure sensor exhibited satisfactory clinical reliability and validity. Furthermore, it may be that for Japanese elderly patients the maximum pressure that can be tolerated by the tissues around the sacrum may be 40-50 mmHg.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0965-206x(02)80023-7 | DOI Listing |
Res Nurs Health
January 2025
College of Nursing, The University of Tennessee, Knoxville, Tennessee, USA.
The social determinants of health (SDOH) have been recognized as an important contributor to an individual's health status. A valid and reliable instrument is needed for researchers and clinicians to measure SDOH. However, there is considerable variability in the screening methodologies, as well as a lack of standardization in definitions and methods for capturing and reporting SDOH data for both electronic health record software vendors and national experts on SDOH.
View Article and Find Full Text PDFPhysiother Res Int
January 2025
Department of Physiotherapy, Centro Universitário FUNCESI, Itabira, Brazil.
Background And Purpose: To develop a new test to assess the motor coordination of the upper limbs, and to investigate the test-retest and inter-rater reliability, construct validity, standard error of measurement (SEM), minimum detectable change (MDC), and the reference values.
Methods: The Upper Extremity Motor Coordination Test (UEMOCOT)was applied for 20 s, with the individual touching two targets (one right and one left) as quickly as possible, first with the hand (manual task) and then with the index finger (finger task). To test-retest reliability, the UEMOCOT was administered two times.
J Holist Nurs
January 2025
University of Central Florida, College of Nursing, Orlando, FL, USA.
The Nurse Practitioner Holistic Caring Instrument (NPHCI) is a 19-item, investigator-developed instrument designed to measure holistic caring in nurse practitioner (NP) practice. This paper evaluates multi-sample psychometric testing of the instrument, describing data from three samples, with analysis supporting the NPHCI as a valid and reliable instrument. Methods: The NPHCI has been administered in patient, NP program faculty, and NP convenience samples.
View Article and Find Full Text PDFEClinicalMedicine
October 2024
Department of Oncology, Queen's University, Kingston, Canada.
Patients with cancer expect prolonged life (overall survival, OS) or better life (quality of life, QOL) from cancer treatments. However, majority of new cancer drugs are now being approved not based on improved OS or QOL, but based on surrogate endpoints such as tumor shrinkage or delayed tumor progression. These surrogate endpoints, including their validity as a proxy for overall survival, differ based on disease settings and lines of treatment but in general, most surrogate measures have weak correlation with outcomes that matter to patients.
View Article and Find Full Text PDFBiosci Microbiota Food Health
September 2024
Core Technology Laboratories, Asahi Quality & Innovations, Ltd., 1-1-21 Midori, Moriya-shi, Ibaraki 302-0106, Japan.
α-Cyclodextrin (αCD), a cyclic hexasaccharide composed of six glucose units, is not digested in the small intestine but is completely fermented by gut microbes. Recently, we have reported that αCD supplementation for nonathlete men improved their 10 km biking times. However, the beneficial effects of αCD on exercise are not yet fully understood.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!