AI Article Synopsis

  • Defines key concepts in automated perimetry, including threshold levels, types of tests, and testing strategies.
  • Outlines the steps for interpreting automated perimetry results, focusing on test types, patient reliability assessment, and visual field defect analysis.
  • Emphasizes the importance of distinguishing between actual defects and artifacts through statistical evaluation.

Article Abstract

In the beginning of the article where are defined the notions of the soft of automated perimetry: threshold, kind of tests, the strategy of automated perimetry. Then are shown the steps of automated perimetry interpretation: kind of test and strategy, evaluation of patient reliability, interpretation of the visual field defects (artifacts or no) and statistical analysis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

automated perimetry
12
visual field
8
[interpretation visual
4
field humphrey
4
humphrey zeiss
4
zeiss analyser]
4
analyser] article
4
article defined
4
defined notions
4
notions soft
4

Similar Publications

Glaucoma poses a growing health challenge projected to escalate in the coming decades. However, current automated diagnostic approaches on Glaucoma diagnosis solely rely on black-box deep learning models, lacking explainability and trustworthiness. To address the issue, this study uses optical coherence tomography (OCT) images to develop an explainable artificial intelligence (XAI) tool for diagnosing and staging glaucoma, with a focus on its clinical applicability.

View Article and Find Full Text PDF

In agriculture, promptly and accurately identifying leaf diseases is crucial for sustainable crop production. To address this requirement, this research introduces a hybrid deep learning model that combines the visual geometric group version 19 (VGG19) architecture features with the transformer encoder blocks. This fusion enables the accurate and précised real-time classification of leaf diseases affecting grape, bell pepper, and tomato plants.

View Article and Find Full Text PDF

Purpose: Alternative non-standard paediatric visual field (VF) tests have been developed to address the challenges associated with standard approaches. However, diagnostic accuracy of these new VF tests has not yet been rigorously evaluated. This systematic review aims to explore diagnostic accuracy and feasibility of non-standard VF tests in paediatric patients.

View Article and Find Full Text PDF

Purpose: This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.

Methods: In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders.

View Article and Find Full Text PDF

Purpose: The purpose of this systematic review was to consolidate and summarize available data comparing virtual reality perimetry (VRP) with standard automated perimetry (SAP) in adults with glaucoma. Understanding the utility and diagnostic performance of emerging VRP technology may expand access to visual field testing but requires evidence-based validation.

Methods: A systematic literature search was conducted in 3 databases (PubMed Central, Embase, and Cochrane Central Register of Controlled Trials) from the date of inception to 10/09/2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!