Objective: The objective of this study was to histologically clarify the difference of vascular wall damage when an ultrasonic scalpel is used in varied ways in the vicinity of a vessel.
Subjects And Methods: 1) The surface of sodium carbonate-containing jelly was manually brushed with the edge of a dissecting hook type Harmonic Scalpel (HS), and the thickness of the air bubble layer was measured to investigate the range to which the vibrations of the instrument reached. 2) The internal thoracic artery (ITA), radial artery (RA) and vein skeletonized were cut bluntly or brushed using HS ex vivo, and tissue damages were observed histologically. 3) The depth of thermal degeneration (TD) of residual stumps of ITAs skeletonized by HS using an output power level (level) of 2 and the quick touch method at the time of coronary arterial bypass grafting (CABG) were investigated histologically.
Results: 1) The mean thickness of the air bubble layers by single brushing was 3.7, 3.7 and 3.1 mm at level 4, 3 and 2, and no significant difference. When brushed 5 times, it was 6.9, 5.5 and 6.7 mm, respectively, showing marked increases compared with single brushing. 2) A: One side of the RA stump cut with a dissecting hook at level 2 was nicely occluded by a degenerated protein coagulum, but the contralateral had no coagulum. An ITA cut by a shear type blade at level 3 showed that both stumps were nicely occluded, but the vessel wall was introverted and fragmented. B: ITAs brushed 5 or 10 times at level 2 showed that TD occurred in tunica externa, the mean depth of 100 or 203 microm, and never exceeded the external elastic lamella. RAs brushed 10 times at level 2 and 3 showed that TD and air bubble generation occurred in the tunica externa, and the mean depth was 203 and 203 microm. However, TD exceeded the external lamella in some cases at level 3. Veins brushed 10 times at level 3 showed that TD spread to all layers. 3) The depth of TD in ITAs skeletonized clinically by HS was 400 to 530 microm, and apart from the external elastic lamella.
Conclusions: 1) Though the air bubble layer was very thick in jelly, it was observed only in tunica externa ex vivo. 2) For coagulation and cut of small blood vessels, it is vital to press an HS blade edge onto the vessel so as to press equally both portions to be cut. There is a possibility of a fragmented and introverted vessel wall into the lumen. 3) By dissecting ITA and RA using HS at level 2 and the quick touch method, TD can be limited to the depth of the connective tissue of tunica externa.
Download full-text PDF |
Source |
---|
Materials (Basel)
December 2024
I2M (Institut de Mécanique et d'Ingénierie), UMR 5295, CNRS, University of Bordeaux, 33400 Talence, France.
From both economic and environmental points of view, the reuse of dredged sediments in the direct onsite casting of concrete represents a promising method for replacing sand. The aim of this study was to develop a cementitious material that (i) reuses the thin particles of sediments; (ii) has a low density due to the incorporation of air foam in the material; and (iii) achieves a minimum mechanical strength of 0.5 MPa for embankment applications.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Department of Cardiac Surgery, Anthea Hospital GVM Care and Research, Via Camillo Rosalba 35/37, 70124 Bari, Italy.
In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which can be insidious and increase the risk of cerebral or myocardial complications. This retrospective study compares the effectiveness of the use of irrigation mist and CO versus a direct CO blower without irrigation in terms of visualization, postoperative fibrillation, and micro-embolic gas activity.
View Article and Find Full Text PDFRetin Cases Brief Rep
January 2025
The Retina Service of Wills Eye Hospital, Wills Eye Physicians-Mid Atlantic Retina, Thomas Jefferson University, Philadelphia, PA.
Purpose: To illustrate a technique for the removal of subretinal gas via pars plana vitrectomy (PPV) with air-fluid exchange and simultaneous manipulation with scleral depression.
Methods: PPV to remove subretinal gas causing persistent macula-off retinal detachment was performed in one eye, and the results were evaluated in this case report. Ports were carefully placed to avoid puncturing the retina, which was significantly displaced anteriorly past the ora serrata due to the buoyancy of the subretinal gas with the patient in a supine position.
Tree Physiol
January 2025
Laboratory of Plant Ecology, Department of Plants and Crops, Faculty of Bioscience Engineering, Ghent University, Belgium.
During drought, the formation of air bubbles known as embolisms in the water-conducting xylem reduces hydraulic conductivity, which can ultimately result in tree death. Accurately quantifying vulnerability to embolism formation is therefore essential for understanding tree hydraulics. Acoustic emission (AE) analysis offers a non-destructive method to monitor this process, yet the interpretation of captured signals remains debated.
View Article and Find Full Text PDFEur J Ophthalmol
January 2025
Cornea and Refractive Surgery Unit, Instituto de Microcirugía Ocular (IMO), Barcelona, 08035, Spain.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!