The influence of flip angle and flow velocity on the signal intensity achieved when imaging a hyperpolarized substance with a spoiled gradient echo sequence was investigated. The study was performed both theoretically and experimentally using hyperpolarized xenon dissolved in ethanol. Analytical expressions regarding the optimal flip angle with respect to signal and the corresponding signal level are presented and comparisons with thermally polarized substances are made. Both experimentally and theoretically, the optimal flip angle was found to increase with increasing flow velocity. Numerical calculations showed that the velocity dependence of the signal differs between the cases of hyperpolarized and thermally polarized substances.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s1090-7807(02)00117-9 | DOI Listing |
Children (Basel)
January 2025
Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital Muenster, 48149 Muenster, Germany.
: Legg-Calvé-Perthes disease (LCPD) presents challenges in treatment due to its varied course and unclear etiology. This study aimed to evaluate the efficacy of combining proximal femoral varus osteotomy (PFVO) with a modified trochanteric flip osteotomy to address biomechanical consequences and improve hip abductor muscle strength. : We present a modified approach combining PFVO with a trochanteric flip osteotomy.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Departments of Radiology (J.F.H., S.Y.C., J.-P.G., J.S., P.N., S.B.R., T.M.G.), Biomedical Engineering (S.B.R., T.M.G.), Medical Physics (S.Y.C., S.B.R., T.M.G.), Medicine (S.B.R.), and Emergency Medicine (S.B.R.), University of Wisconsin-Madison, WI; and Department of Diagnostic and Interventional Radiology (J.F.H., J.-P.G.), University Hospital Würzburg, Würzburg, Germany.
Rationale And Objectives: Pulmonary magnetic resonance angiography (MRA) is an imaging method with proven utility for the exclusion of pulmonary embolism and avoids the need for ionizing radiation and iodinated contrast agents. High-relaxivity gadolinium-based contrast agents (GBCAs), such as gadopiclenol, can be used to reduce the required gadolinium dose for pulmonary MRA. The aim of this study was to compare the contrast enhancement performance of gadopiclenol with an established gadobenate dimeglumine-enhanced pulmonary MRA protocol.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology and Imaging Sciences, University of Utah Health, Salt Lake City, Utah, USA.
Purpose: The single reference variable flip angle sequence with a multi-echo stack of stars acquisition (SR-VFA-SoS) simultaneously measures temperature change using proton resonance frequency (PRF) shift and T-based thermometry methods. This work evaluates SR-VFA-SoS thermometry in MR-guided focused ultrasound in an in vivo rabbit model.
Methods: Simultaneous PRF shift thermometry and T-based thermometry were obtained in a New Zealand white rabbit model (n = 7) during MR-guided focused ultrasound surgery using the SR-VFA-SoS sequence at 3 T.
Biophys J
January 2025
Department of Chemistry and Biochemistry, University of Windsor, Windsor, Ontario, Canada. Electronic address:
α-Tocopherol (αtoc, vitamin E) is an essential nutrient sufficiently acquired through a balanced diet. This fat-soluble vitamin is most known for its antioxidative properties, however, its fundamental mechanism of action in cellular membranes remains unknown. To this end, we use time-resolved small angle neutron scattering (TR-SANS) and a contrast matching scheme to determine intervesicular exchange (k) and intrabilayer flip-flop (k) rates of αtoc in 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) vesicles.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology, Stanford University, Stanford, California, USA.
Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal-to-noise ratio is limited by the field strength and k-space sampling speed is limited by a lower specification gradient system.
Methods: We adapted the three-dimensional spiral projection imaging MR fingerprinting approach to 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!