The evaluation of left ventricular ejection fraction (LVEF) may be troublesome in difficult clinical settings in patients with coronary artery disease (CAD). The aim of this study was to compare 2 simple geometrical and nongeometrical methods of LVEF evaluation that could overcome the typical technical limitations of ultrasound examination. The authors studied 26 patients with proven CAD (63+/-10 years) who underwent left ventricular (LV) catheterization and coronary angiography during the hospital stay. A complete 2D-Doppler echocardiography was performed and LVEF was evaluated with the formula by Wyatt (W-LVEF), which relates the left ventricle to a biplane ellipsoidal figure, and by the myocardial performance index (MPI) formula (MPI-LVEF), MPI being an index of systodiastolic function. Mean MPI-LVEF was 41+/-8% and was significantly lower with respect to contrast angiography (52+/-14%, p = 0.0003) and to W-LVEF (49+/-13%, p = 0.0009). There was no statistically significant correlation between MPI-LVEF and geometric (either angiographic or ultrasound) LVEF. Bland-Altman analysis showed lack of agreement between MPI-LVEF and any other method evaluated in the study. MPI-LVEF may not be reliable and accurate for the evaluation of systolic function in patients with CAD. Nonetheless, the evaluation of global LV function by means of MPI may represent a valuable and affordable alternative to expensive and time-consuming methods, especially in the presence of difficult technical settings.

Download full-text PDF

Source
http://dx.doi.org/10.1177/000331970205300610DOI Listing

Publication Analysis

Top Keywords

left ventricular
12
evaluation left
8
ventricular ejection
8
ejection fraction
8
patients coronary
8
coronary artery
8
artery disease
8
evaluation
5
mpi-lvef
5
comparison methods
4

Similar Publications

[Clinical characteristics and pharmacological treatment of patients with heart failure in a primary health care cohort].

Aten Primaria

January 2025

Fundació Institut Universitari per a la Recerca a l'Atenció Primària de Salut Jordi Gol i Gurina (IDIAPJGol), Barcelona, España; Department of Pharmacology, Therapeutics and Toxicology, Universitat Autònoma de Barcelona, Bellaterra, Cerdanyola del Vallès, Barcelona, España; Institut Català de la Salut, Barcelona, España.

Objective: To characterise patients with heart failure (HF) in Primary Health Care (PHC) and describe their socio-demographic and clinical characteristics and pharmacological treatment.

Design: Descriptive cohort study. SITE: Information System for the Development of Research in Primary Care (SIDIAP), which captures information from the electronic health records of PHC of the Catalan Institute of Health (approximately 80% of the Catalan population).

View Article and Find Full Text PDF

Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.

Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.

View Article and Find Full Text PDF

This paper proposes the use of artificial intelligence techniques, specifically the nnU-Net convolutional neural network, to improve the identification of left ventricular walls in images of myocardial perfusion scintigraphy, with the objective of improving the diagnosis and treatment of coronary artery disease. The methodology included data collection in a clinical environment, followed by data preparation and analysis using the 3D Slicer Platform for manual segmentation, and subsequently, the application of artificial intelligence models for automated segmentation, focusing on the efficiency of identifying the walls of the left ventricular. A total of 83 clinical routine exams were collected, each exam containing 50 slices, which is 4,150 images.

View Article and Find Full Text PDF

Biomarkers of RV Dysfunction in HFrEF Identified by Direct Tissue Proteomics: Extracellular Proteins Fibromodulin and Fibulin-5.

Circ Heart Fail

January 2025

First Faculty of Medicine, Biotechnology and Biomedicine Center of the Academy of Sciences and Charles University (BIOCEV), Charles University, Prague, Czech Republic. (M.B., D.L., O.V., J.P.).

Background: Right ventricular dysfunction (RVD) is common in patients with heart failure with reduced ejection fraction, and it is associated with poor prognosis. However, no biomarker reflecting RVD is available for routine clinical use.

Methods: Proteomic analysis of myocardium from the left ventricle and right ventricle (RV) of patients with heart failure with reduced ejection fraction with (n=10) and without RVD (n=10) who underwent heart transplantation was performed.

View Article and Find Full Text PDF

Objectives: Supra-normal left ventricular ejection fraction (snLVEF) represents a heterogeneous group with distinct prognoses. Left atrial (LA) strain, measured by speckle tracking echocardiography (STE), is a validated prognostic indicator. This study aimed to evaluate LA and left ventricular (LV) mechanical strains in hypertensive patients with snLVEF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!