Across a variety of species, including humans, it has been shown that embryos exposed to ethanol display eye abnormalities as well as deficiencies in visual physiology and behavior. The purpose of this study was to examine the effects of embryonic exposure to ethanol on visual function in zebrafish. Visual function was assessed physiologically, via electroretinogram (ERG) recordings, and behaviorally, by measuring visual acuity with the optomotor response. Zebrafish larvae were exposed to 1.5% ethanol at various times during development, including the period of maximal eye development. The results show that ethanol effects on visual function were most pronounced when exposure occurred during eye development. ERG recordings from ethanol-exposed larvae differed from normal subjects both in shape of the response waveform and in visual thresholds under both light and dark adaptation; the differences were more pronounced under lower levels of adaptation. Also, ethanol-exposed larvae displayed lower visual acuity as determined from the optomotor response. These results indicate embryonic ethanol exposure affects visual function particularly when exposure occurs during eye development. In addition, these findings illustrate the usefulness of the zebrafish as a viable animal model for studying Fetal Alcohol Syndrome (FAS).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0892-0362(02)00319-7 | DOI Listing |
J Orthop Traumatol
January 2025
Department of Orthopaedic Trauma, Hong Hui Hospital, Xi'an Jiaotong University School of Medicine, Xi'an, 710054, Shaanxi, China.
Background: Clavicle fractures associated with ipsilateral coracoid process fractures are very rare, with limited literature reporting only a few cases. This study reports on 27 patients with ipsilateral concomitant fractures of the clavicle and coracoid process who were followed for more than 12 months.
Material And Methods: This retrospective study reviewed the charts of skeletally mature patients with traumatic ipsilateral clavicle and coracoid process fractures treated at the authors' institution.
Ophthalmic Physiol Opt
January 2025
School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.
Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.
Ophthalmic Physiol Opt
January 2025
Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.
Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Institute of Sport, Exercise & Health, Tianjin University of Sport, Tianjin, China.
Background: Patellofemoral pain syndrome (PFPS) is a common disorder affecting the lower extremity. This study aimed to compare the effects of functional strength training (FST) and standard strength training (SST) in PFPS patients.
Methods: Forty college students (aged 18-30 years) with PFPS and no exercise habits were randomized into FST group (n = 20) and SST group (n = 20).
J Neuroeng Rehabil
January 2025
Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Vita Stråket 12, Floor 4, 41346, Gothenburg, Sweden.
Background: Myoelectric pattern recognition (MPR) combines multiple surface electromyography channels with a machine learning algorithm to decode motor intention with an aim to enhance upper limb function after stroke. This study aims to determine the feasibility and preliminary effectiveness of a novel intervention combining MPR, virtual reality (VR), and serious gaming to improve upper limb function in people with chronic stroke.
Methods: In this single case experimental A-B-A design study, six individuals with chronic stroke and moderate to severe upper limb impairment completed 18, 2 h sessions, 3 times a week.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!