Background: Anesthesia simulators can generate reproducible, standardized clinical scenarios for instruction and evaluation purposes. Valid and reliable simulated scenarios and grading systems must be developed to use simulation for evaluation of anesthesia residents.
Methods: After obtaining Human Subjects approval at each of the 10 participating institutions, 99 anesthesia residents consented to be videotaped during their management of four simulated scenarios on MedSim or METI mannequin-based anesthesia simulators. Using two different grading forms, two evaluators at each department independently reviewed the videotapes of the subjects from their institution to score the residents' performance. A third evaluator, at an outside institution, reviewed the videotape again. Statistical analysis was performed for construct- and criterion-related validity, internal consistency, interrater reliability, and intersimulator reliability. A single evaluator reviewed all videotapes a fourth time to determine the frequency of certain management errors.
Results: Even advanced anesthesia residents nearing completion of their training made numerous management errors; however, construct-related validity of mannequin-based simulator assessment was supported by an overall improvement in simulator scores from CB and CA-1 to CA-2 and CA-3 levels of training. Subjects rated the simulator scenarios as realistic (3.47 out of possible 4), further supporting construct-related validity. Criterion-related validity was supported by moderate correlation of simulator scores with departmental faculty evaluations (0.37-0.41, P < 0.01), ABA written in-training scores (0.44-0.49, < 0.01), and departmental mock oral board scores (0.44-0.47, P < 0.01). Reliability of the simulator assessment was demonstrated by very good internal consistency (alpha = 0.71-0.76) and excellent interrater reliability (correlation = 0.94-0.96; P < 0.01; kappa = 0.81-0.90). There was no significant difference in METI versus MedSim scores for residents in the same year of training.
Conclusions: Numerous management errors were identified in this study of anesthesia residents from 10 institutions. Further attention to these problems may benefit residency training since advanced residents continued to make these errors. Evaluation of anesthesia residents using mannequin-based simulators shows promise, adding a new dimension to current assessment methods. Further improvements are necessary in the simulation scenarios and grading criteria before mannequin-based simulation is used for accreditation purposes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00000542-200212000-00015 | DOI Listing |
Cureus
December 2024
Urology, Université Saint-Joseph, Hôtel-Dieu de France University Hospital, Beirut, LBN.
Introduction and aim Laparoscopic surgery has revolutionized the field of surgery over the past few decades. The learning curve in laparoscopy is known to be slow, flat, and complex. This study aims to conduct a comparative analysis of laparoscopic skills, specifically focusing on suturing, knot tying, and needle handling, between novices and experts.
View Article and Find Full Text PDFJ Anaesthesiol Clin Pharmacol
October 2024
Department of Anesthesiology and Intensive Care, Faculty of Medicine Universitas Indonesia - Cipto Mangunkusumo Hospital, Indonesia.
Background And Aims: Inhalation anesthetics is basic knowledge that must be mastered by an anesthesiologist. Lack of competencies can result in higher morbidity and mortality in anesthesiology practice. Various learning methods were developed to improve understanding and retention.
View Article and Find Full Text PDFRadiol Case Rep
March 2025
Resident at Radiology Department, French Medical Institute for Mothers and Children (FMIC), Kabul, Afghanistan.
Iatrogenic intracranial hypotension is a known complication of spinal anesthesia that can lead to more severe conditions, such as dural or cerebral venous sinus thrombosis (CVST). This report presents a case of intracranial hypotension in a young woman after lumbar anesthesia for a cesarean section that was complicated by CVST and subsequently by lobar hemorrhage, clinically presenting with severe headache and seizures. The diagnosis was made via cerebral magnetic resonance (MR) imaging, and the patient was treated medically.
View Article and Find Full Text PDFInjury
December 2024
Department of Surgical Sciences, University of Turin, 10124, Turin, Italy.
Purpose: Several concerns regarding gender equality in orthopedic surgery do exists. The aim of this study was to (1) compare operative times, (2) compare mortality rates, (3) investigate gender disparities in hip fracture surgeries, and (4) analyze gender distribution among attending and resident surgeons performing Closed Reduction Internal Fixation (CRIF) and Hemiarthroplasty (HA) METHODS: All patients >75 years old treated for proximal femur fractures in a level-one trauma center in a four-year timeframe were retrospectively enrolled. Exclusion criteria were follow-up <3 years, incomplete data, active patients treated with total hip arthroplasty (THA) and other surgeries performed during the same anesthesia.
View Article and Find Full Text PDFInt J Obstet Anesth
December 2024
Department of Biomedical Engineering and the School of Brain Sciences and Cognition, Ben Gurion University of the Negev, Beer Sheva, Israel.
Background: Correct identification of the epidural space requires extensive training for technical proficiency. This study explores a novel bimanual haptic simulator designed for the precise insertion of an epidural needle based on loss-of-resistance (LOR) detection, providing realistic dual-hand force feedback.
Methods: The simulator, equipped with two haptic devices connected to a Tuohy needle and an LOR syringe, was designed to simulate the tissues' resistive forces felt by the user during the procedure, offer anatomical variability and record detailed performance metrics for personalized feedback.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!